TrojanTwo User Guide v3.8
Page | 38
10.4
Gap size and speeds
The minimum gap size and speed has a dependency due to the image processing in the print head.
Therefore, we recommend these minimum gap size settings:
Speed
Minimum gap size
6 inches per second / 9 meters per minute
2.2 mm
12 inches per second / 18 meters per minute
3 mm
NOTE:
the complexity of the image may also influence this. A very simple bar code image may allow for
shorted gap sizes.
TrojanTwo will display an error in the ‘Error’-field: ‘Missed TOF – datapath underrun’ if this occurs.
11
Shutting down the TrojanTwo press
Shut down procedure:
1.
Go to HOME tab
2.
Press ‘Shut down’ menu
3.
Press the big red ‘Shutdown TrojanController’ button
4.
Reconfirm by selecting ok.
5.
Green info button is displayed, no need to press ok on that button
6.
After shutting down the machine, turn off the power switch at the back of the machine to cut down
power from the Power Supply Units.