Excite electric shower
13
The first operation of the shower is intended to
flush out any remaining unit debris and to make
sure the heater unit contains water before the
elements are switched on.
This operation must be carried out with the
flexible hose screwed to the outlet but WITHOUT
the showerhead attached.
Make sure the outlet from the flexible hose is
directed to waste.
Before switching on the electric and mains water
supplies to the shower, check that the power
selector is in the COLD position
(fig.20)
and
the temperature control is turned to number 10,
the minimum flow position
(fig.20)
.
Note:
Failure to turn the control to number 10
may cause the PRD to operate.
Turn on the electric and mains water supplies to
the shower. The power indicator will light.
Press the Start/Stop button
(fig.20)
and wait
until water starts to flow from the flexible hose.
Slowly turn the temperature control fully anti-
clockwise to number 1, the maximum flow
position
(fig.21)
.
It will take about thirty seconds for a smooth
flow of water to be obtained while air and any
debris is being flushed from the shower.
When there is a smooth flow of water turn the
temperature control from 1 to 10 and back
again several times to release any trapped air
within the unit.
Once flushing out has been completed, stop the
water flow by pressing the Start/Stop button.
Fit the showerhead to the flexible hose and place
in the showerhead holder.
The shower is now ready for normal operation.
Commissioning
COMMISSIONING
T00412
Start/Stop switch
assembly
Fig.19
Fig.20
Fig.21
Temperature
control setting at
minimum flow
Start/Stop
button
Power selector
to COLD
Temperature
control setting at
maximum flow