Excite electric shower

12

Refit the trimplate. Turn the POWER selector 
spindle clockwise to the position shown in 

fig.14

.

Turn the stabiliser valve spindle fully clockwise 
until resistance is felt 

(fig.15)

.

On the cover turn the power selector to the 
COLD position 

(fig.16) 

then

 

rotate the 

temperature control so that it points to the 
number 10 

(fig.17)

.

IMPORTANT:

 Before finally fitting the cover, 

the following steps must be taken:

a.

  Check the plumbing connections are 

watertight.

b.

  Check the terminal block screws are fully 

tightened.

c.

  Make sure the pipe and cable entering 

the unit do not prevent the cover locating 
correctly to the backplate.

d.

  Check the power selector is in the STOP 

position and the temperature control is in 
the number 10 position.

Offer the cover to the unit.
Plug the two neons located on the backplate 
onto the bracket inside the cover 

(fig.18)

. The 

neon with the yellow wires clips into the upper 
position and the remaining neon fits into the 
lower position. 
Attached to the START/STOP switch inside the 
cover is a two-wire lead. Connect the socket on 
the end of the lead to the plug leading from the 
backplate

 (fig.19)

.

Note:

 The plug and socket can only fit one way.

Carefully locate the cover tags into the guide 
pockets on the backplate and make sure the 
wires are not trapped. 

Note:

 DO NOT remove the cable ties in this 

unit. 
Guide the cover into position so that the knob 
spindle locates correctly (minor adjustment may 
be necessary to align the knob and spindle).
Should any difficulty arise, recheck the points 
above.
While applying slight pressure to the front cover, 
secure in place using the three retaining screws.

Replacing the cover

REPLACING THE COVER

 T00406

Fig.14

 T00390

>POM-GF30<

Valve

spindle

Fig.15

 T00411

Yellow wires

(power neon)

Fig.18

Fig.16

Fig.17

Power selector  

to COLD

Temperature control  

setting at minimum flow

WARNING

COVER RETAINING SCREWS

ONLY

 the 

SUPPLIED SCREWS

 should be 

used. The use of none supplied screws 

WILL

 

invalidate product specifications & warranty.

Summary of Contents for Excite Eco

Page 1: ...s Excite Eco electric shower 2180695E April 2018 Installers please note these instructions are to be left with the user ECO STATEMENT This product has been designed to deliver an average flow of below...

Page 2: ...ts diagram 21 Guarantee service policy etc rear cover CONTENTS Page To check the product suitability for commercial and multiple installations please contact Triton s specification advisory service be...

Page 3: ...nd could also cause the PRD Pressure Relief Device in the unit to operate 1 9 This product is not suitable for mounting into steam rooms or steam cubicles 2 PLUMBING 2 1 The plumbing installation must...

Page 4: ...ter becomes too hot and you cannot obtain cooler water first check that the sprayplate in the showerhead has not become blocked DO NOT place items such as soap or shampoo bottles on top of the unit Li...

Page 5: ...ry area 6 Wall screw fixing 7 Terminal block 8 Power selector 9 Stabilising valve 10 Solenoid valve 11 Guide pockets 12 Can and element assembly 13 Thermal cut out main 14 Earth connection 15 Pressure...

Page 6: ...bt switch off the whole installation at the mains supply and remove the correct fuse 3 The shower must be connected to its own independent electrical circuit IT MUST NOT be connected to a ring main sp...

Page 7: ...ng in a bath or shower cubicle It should be readily accessible to switch off after using the shower 7 Where shower cubicles are located in any rooms other than bathrooms all socket outlets in those ro...

Page 8: ...tic pressure must be no greater than 1000kPa 10 bar If in any doubt the pressure should be checked Note If the stated flow rates are not available it may not be possible to achieve optimum performance...

Page 9: ...wall always mount the unit on the surface of the tiles NEVER tile up to the unit Refer to fig 6 for the correct siting of the shower Position the unit where it will NOT be in direct contact with water...

Page 10: ...ce cable entry from the top is required then a small area will need to be cut out in the backplate fig 9 If installing a feed pipe from the rear bottom or side the centre of the inlet valve to the wal...

Page 11: ...the wall Hook the backplate over the top and bottom screws and fit the centre fixing screw into position Do not fully tighten the screws at this stage as the fixing holes are elongated to allow for ou...

Page 12: ...ve all swarf and system debris This can be achieved by connecting a hose to the pipework and turning on the mains water supply long enough to clear the debris to waste Procedure Turn off water supply...

Page 13: ...rews Loose connections can result in cable overheating Note The supply cable earth conductor must be sleeved The outer sheath of the supply cable must be stripped back to the minimum The supply cable...

Page 14: ...s into the upper position and the remaining neon fits into the lower position Attached to the START STOP switch inside the cover is a two wire lead Connect the socket on the end of the lead to the plu...

Page 15: ...power indicator will light Press the Start Stop button fig 20 and wait until water starts to flow from the flexible hose Slowly turn the temperature control fully anti clockwise to number 1 the maxim...

Page 16: ...t due to low water pressure it will be necessary to operate the unit on this setting during the warmer months because of flow rate limitations entering the unit The red symbol T00402 is a high power s...

Page 17: ...be a time delay of a few seconds between selecting a flow rate and the water reaching the stable temperature for that flow rate CAUTION It is recommended that persons who may have difficulty understan...

Page 18: ...as cooled sufficiently power to the elements will be automatically restored to the settings at the time of interruption Safety cut out The unit is fitted with a non resettable thermal cut out safety d...

Page 19: ...or service engineer IMPORTANT Before servicing switch off both the electricity supply and water supply at the mains The inlet filter is situated in the side of the inlet pipe fig To gain access to th...

Page 20: ...ely Power selector S12121011 Thermal cut out 22011180 Stabiliser valve Solenoid assembly P12120806 Pressure relief device PRD 82800450 Heater can assembly 8 5kW P12120701 Start Stop switch assembly 82...

Page 21: ...educe flow rate via temperature control Is water supply mains or tank fed If tank fed replumb to mains water supply or see 4 2 4 If mains fed make sure that the mains stopvalve is fully open and there...

Page 22: ...4 2 4 4 3 1 4 3 2 4 4 1 5 1 1 6 1 1 6 2 1 6 3 1 6 4 1 7 1 1 7 2 1 7 3 1 required see rating label Reduction in ambient water temperature Electrical malfunction or safety cut out operated Water pressur...

Page 23: ...y registered with the Environment Agency under the following schemes Repic Producers take back scheme PTS registration number WEE EJ3466QV Valpak Distributor take back scheme DTS registration number 9...

Page 24: ...ers Card Payment can also be made by pre payment of a pro forma invoice by cheque or postal order Telephone orders are based on information given during the call Before contacting Triton please verify...

Reviews: