Excite electric shower

1

Products manufactured by Triton are safe and without risk provided they are installed, used and 

maintained in good working order in accordance with our instructions and recommendations.

WARNING:

 

DO NOT

 operate shower if frozen, or suspected of being frozen. It must thaw out 

before using.

DO NOT

 operate the unit if the showerhead or spray hose becomes damaged.

DO NOT

 restrict flow out of shower by placing showerhead in direct contact with your body.

DO NOT

 operate the shower if water ceases to flow during use or if water has entered inside 

the unit because of an incorrectly fitted cover.

WARNING:

 If restarting the shower immediately after stopping, be aware that a slug of 

hot water will be expelled for the first few seconds.

PLEASE READ THIS IMPORTANT SAFETY INFORMATION

GENERAL

1.1 

Isolate the electrical and water supplies before 

removing the cover.

1.2 

Read all of these instructions and retain them 

for later use.

1.3 

DO NOT

 take risks with plumbing or electrical 

equipment.

1.4 

Isolate electrical and water supplies before 

proceeding with the installation.

1.5 

The unit must be mounted onto the finished 

wall surface (on top of the tiles). 

DO NOT

 tile 

up to or seal around 

ANY PART

 of the unit 

using silicone sealer after fixing to the wall. 

Special care must be taken 

NOT TO BLOCK 

OR SEAL ANY PRD VENTS ON THE UNIT

.

1.6 

Contact Customer Service 

(see back page)

, if 

any of the following occur:

a) 

If it is intended to operate the shower at 

pressures above the maximum or below the 

minimum stated.

b) 

If the unit shows a distinct change in performance.

c) 

If the shower is frozen.

1.7 

If it is intended to operate the shower in areas 

of hard water (above 200 ppm temporary 

hardness), a scale inhibitor may have to be 

fitted. For advice on the Scale Inhibitor, 

contact Customer Service.

1.8 

The showerhead must be cleaned regularly 

with descalent to remove scale and debris, 

otherwise restrictions to the flow on the outlet 

of the unit will result in higher temperatures 

and could also cause the (PRD) Pressure Relief 

Device in the unit to operate.

1.9 

This product is not suitable for mounting into 

steam rooms or steam cubicles.

PLUMBING

2.1 

The plumbing installation must comply with 

Water Regulations, Building Regulations or any 

particular regulations as specified by Local 

Water Company or Water Undertakers and 

should be in accordance with BS EN 806.

2.2 

The supply pipe must be flushed to clear debris 

before connecting to the shower unit.

2.3  DO NOT

 solder pipes or fittings within 300mm 

of the shower unit, as heat can transfer along 

the pipework and damage components.

2.4  DO NOT

 fit any form of outlet flow control as 

the outlet acts as a vent for the heater can.

2.5  DO NOT

 use excessive force when making 

connections to the flexible hose or 

showerhead, finger tight is sufficient.

2.6 

All plumbing connections must be completed 

before making the electrical connections.

2.7 

This appliance 

MUST 

not be connected to the 

inlet supply by a hose-set.

ELECTRICAL

3.1 

The installation must comply with BS 7671 

‘Requirements for electrical installations’ (IEE 

wiring regulations), building regulations or any 

particular regulations as specified by the local 

Electrical Supply Company.

3.2 

This appliance 

MUST 

be earthed.

3.3 

In accordance with ‘The Plugs and Sockets etc. 

(Safety) Regulations 1994’, this appliance is 

intended to be permanently connected to the 

fixed wiring of the electrical mains system.

3.4 

Make sure all electrical connections are tight to 

prevent overheating.

3.5 

A 30mA residual current device (RCD) 

MUST 

be installed in all UK electric and pumped 

shower circuits. This may be part of the 

consumer unit or a separate unit.

3.6 

Switch off immediately at isolating switch if 

water ceases to flow during use.

3.7 

Other electrical equipment i.e. extractor fans, 

pumps must not be connected to the circuits 

within the unit.

3.8 

Switch off at isolating switch when not in use. 

This is a safety procedure recommended with 

all electrical appliances.

3.9 

As with all electrical appliances it is 

recommended to have the shower and 

installation checked at least every two years by 

a competent electrician to ensure there is no 

deterioration due to age and usage.

Summary of Contents for Excite Eco

Page 1: ...s Excite Eco electric shower 2180695E April 2018 Installers please note these instructions are to be left with the user ECO STATEMENT This product has been designed to deliver an average flow of below...

Page 2: ...ts diagram 21 Guarantee service policy etc rear cover CONTENTS Page To check the product suitability for commercial and multiple installations please contact Triton s specification advisory service be...

Page 3: ...nd could also cause the PRD Pressure Relief Device in the unit to operate 1 9 This product is not suitable for mounting into steam rooms or steam cubicles 2 PLUMBING 2 1 The plumbing installation must...

Page 4: ...ter becomes too hot and you cannot obtain cooler water first check that the sprayplate in the showerhead has not become blocked DO NOT place items such as soap or shampoo bottles on top of the unit Li...

Page 5: ...ry area 6 Wall screw fixing 7 Terminal block 8 Power selector 9 Stabilising valve 10 Solenoid valve 11 Guide pockets 12 Can and element assembly 13 Thermal cut out main 14 Earth connection 15 Pressure...

Page 6: ...bt switch off the whole installation at the mains supply and remove the correct fuse 3 The shower must be connected to its own independent electrical circuit IT MUST NOT be connected to a ring main sp...

Page 7: ...ng in a bath or shower cubicle It should be readily accessible to switch off after using the shower 7 Where shower cubicles are located in any rooms other than bathrooms all socket outlets in those ro...

Page 8: ...tic pressure must be no greater than 1000kPa 10 bar If in any doubt the pressure should be checked Note If the stated flow rates are not available it may not be possible to achieve optimum performance...

Page 9: ...wall always mount the unit on the surface of the tiles NEVER tile up to the unit Refer to fig 6 for the correct siting of the shower Position the unit where it will NOT be in direct contact with water...

Page 10: ...ce cable entry from the top is required then a small area will need to be cut out in the backplate fig 9 If installing a feed pipe from the rear bottom or side the centre of the inlet valve to the wal...

Page 11: ...the wall Hook the backplate over the top and bottom screws and fit the centre fixing screw into position Do not fully tighten the screws at this stage as the fixing holes are elongated to allow for ou...

Page 12: ...ve all swarf and system debris This can be achieved by connecting a hose to the pipework and turning on the mains water supply long enough to clear the debris to waste Procedure Turn off water supply...

Page 13: ...rews Loose connections can result in cable overheating Note The supply cable earth conductor must be sleeved The outer sheath of the supply cable must be stripped back to the minimum The supply cable...

Page 14: ...s into the upper position and the remaining neon fits into the lower position Attached to the START STOP switch inside the cover is a two wire lead Connect the socket on the end of the lead to the plu...

Page 15: ...power indicator will light Press the Start Stop button fig 20 and wait until water starts to flow from the flexible hose Slowly turn the temperature control fully anti clockwise to number 1 the maxim...

Page 16: ...t due to low water pressure it will be necessary to operate the unit on this setting during the warmer months because of flow rate limitations entering the unit The red symbol T00402 is a high power s...

Page 17: ...be a time delay of a few seconds between selecting a flow rate and the water reaching the stable temperature for that flow rate CAUTION It is recommended that persons who may have difficulty understan...

Page 18: ...as cooled sufficiently power to the elements will be automatically restored to the settings at the time of interruption Safety cut out The unit is fitted with a non resettable thermal cut out safety d...

Page 19: ...or service engineer IMPORTANT Before servicing switch off both the electricity supply and water supply at the mains The inlet filter is situated in the side of the inlet pipe fig To gain access to th...

Page 20: ...ely Power selector S12121011 Thermal cut out 22011180 Stabiliser valve Solenoid assembly P12120806 Pressure relief device PRD 82800450 Heater can assembly 8 5kW P12120701 Start Stop switch assembly 82...

Page 21: ...educe flow rate via temperature control Is water supply mains or tank fed If tank fed replumb to mains water supply or see 4 2 4 If mains fed make sure that the mains stopvalve is fully open and there...

Page 22: ...4 2 4 4 3 1 4 3 2 4 4 1 5 1 1 6 1 1 6 2 1 6 3 1 6 4 1 7 1 1 7 2 1 7 3 1 required see rating label Reduction in ambient water temperature Electrical malfunction or safety cut out operated Water pressur...

Page 23: ...y registered with the Environment Agency under the following schemes Repic Producers take back scheme PTS registration number WEE EJ3466QV Valpak Distributor take back scheme DTS registration number 9...

Page 24: ...ers Card Payment can also be made by pre payment of a pro forma invoice by cheque or postal order Telephone orders are based on information given during the call Before contacting Triton please verify...

Reviews: