Changing Modem Modes (Responder/Transponder/Modem)
Micron Modem
0630-SOM-00001, Issue: 03
19
© Tritech International Ltd.
The
SEAHUBNAV100
and
MINIATTSEN
device types should be visible in the
Setup
window.
The MicronNav100 Hub must now be configured to communicate directly to the Transponder/
Responder in order to carry out the conversion. In
Seanet Setup
click the
Action
column
in the
SEAHUBNAV100
row followed by
Setup
from the drop-down menu that appears to
display the
SeaHub Setup
page. Set
Port B
to
RS232
.
Confirm the settings and close the
SeaHub Setup
page. After a few seconds, the
reprogramming of the unit will be complete and "Node 90, Prog Cfg Done" will be displayed in
the status box. The
SEAHUBNAV100
table entry will temporarily disappear from the list while
the unit resets to activate the change.
Configure the baud rate of
Port B
by selecting
Com Setup
from the
Utilities
menu.
Open the
Channel Setup
page, click on
Settings
in the SeaHubB row to open the
AifSetupForm
and adjust the
Baud
to 57600.
Confirm the settings and close the
AifSetupForm
.
The
Channel Setup
page should now list the enabled ports as follows:
Device
Baud Rate
Type
Aif
115200
SeaHubMain
AMNavSeaNavHS
115200
SeaHubHS
Aif
57600
SeaHubE
Aif
57600
SeaHubB