4. Operation
4.1. Software
Tritech International Ltd
does not supply the Micron Data Modem with specific operating
software. Seanet Pro software is required should any modem re-configuration be required
(refer to Chapter 5,
Any terminal software may be used to operate and test a pair of data modems, however,
they will normally be used as part of a larger system, the hardware of which will take control
of the data transfer process
As standard the Micron Data Modem is configured to communicate on RS232 at 9600Bd,
8 data bits, 1 stop bit and no parity by default. Other rate options are possible although the
device is not configurable once in the field. If the settings of a particular device are unknown
contact
Tritech International Ltd
Technical Support providing the serial number and any of
the original purchase details (if known).
4.2. Integration Considerations
A pair of Micron Data Modems may be used in the following basic configuration:
Figure 4.1. Pair of Micron Modems in Use
The following points should be noted:
• The terms "Master" and "Slave" in Figure 4.1, “Pair of Micron Modems in Use” are used
purely as an aid to system description. Either unit can transmit to and receive from the