Micron Modem
0630-SOM-00001, Issue: 03
17
© Tritech International Ltd.
6. Maintenance
There are no user serviceable components in the Micron Modem and there is no reason to
dismantle the device.
Wash down with fresh water each time the Micron Modem is recovered from the water, paying
particular attention to the transducer and connector.
Although the Micron Modem is designed for a wide temperature range it is best to avoid
temperature extremes for long periods and protect the device from bright sunlight.
It is recommended that usage logs are maintained and that the heads are returned to the
vendor at 4000 hour intervals for routine inspection and replacement of o-ring seals.
Any cables that are supplied with the Micron Modem are high quality with low halogen jackets
and should provide long service life without problems. Care should be taken to ensure that
they are properly sited during installation to avoid movement and fatigue but otherwise no
maintenance is required.