E Series Ethernet Radio – User Manual
LAN Ethernet Port
The LAN port is a 10/100 Base-T compliant port using an RJ-45
connector. These ports support both TIA/EIA-568-A & B wiring as they
have Auto MDI/MDIX Auto Sensing. This means you can use both
straight-through and cross-over type CAT-5 or better patch cables.
All RJ45 connectors must utilize mating plugs that include an integral
locking tab.
If termination of a cable is required, then the following wiring
arrangement should be followed (Compliant with TIA/EIA-568-A).
Note: Maximum differential voltage : 5v, 50mA max through each differential pair.
Note: If 100-BaseT connection speed is required, CAT-6 Shielded
cable should be used for installation to comply with ETSI EMC
directives.
Performing a Factory Default
Please read the following notes carefully. Configuration errors
with Ethernet connections can be difficult to find and resolve. It
is strongly recommended that you follow these guidelines.
IP Address and Factory Default Reset
The factory default IP address of an E Series Ethernet radio is
192.168.2.15
. If you do not know the IP address of the E Series
Ethernet radio you can either read the unit using the TVIEW
programmer or perform a factory default.
A factory reset will cause all previous configuration settings to be
erased and returned to the factory default values. A factory default
can be initiated by applying DC power to the radio (wait 45 seconds),
depress the factory default switch using a paper clip or similar object
and keep the switch depressed for 5 seconds until all five LEDs
illuminate solid GREEN indicating the radio will return to the factory
default settings. Please wait 45 seconds for the factory default reset
process to complete.