Mentor XL
2.
INSTALLATION
2.1
U
NPACKING
Carefully unpack the unit from its transit material and check the unit for signs of damage. Check the
contents of the box against our despatch note and your original order to ensure that you have
received the correct parts.
In the event that the unit has been damaged or does not match your order, immediately contact
your supplier or Trilogy at the address given at the front of this guide.
2.2
R
ACK
M
OUNTING
The 1U rack frame has integral 19" mounting ears for direct mounting in a standard 19" rack.
Carefully place the unit in your rack and firmly attach it to the rack using 4 bolts.
IMPORTANT: This unit has air intakes on one side of the unit and fan assisted exhaust vents on the
other side of the unit. Ensure that these have an unobstructed air flow, otherwise the unit will
overheat. Pay particular attention to ensure that any rack wiring or cable trays do not obstruct the
vent. 60mm of clear space should be allowed between the vents and any potential obstruction.
2.3
E
ARTHING
R
EQUIREMENTS
The unit is provided with a single 4mm earthing stud on the rear panel. Incoming mains earth from
the IEC connector is internally bonded to both the chassis and technical 0V to meet safety
requirements and performance specifications. The stud allows the addition of an earth strap, if
required, in rack installations.