Memory Full Messages
The codes shown below are displayed on the Seeker D display
screen as “FL#” to indicate the internal memory status of the
Seeker D and the optional Seeker MCA III.
“FL##”
Code
Error Description
0
MCA internal memory is full. Shows after “CA0” if there are less than 30,000
records available. This display is cleared by a button press on the Seeker D
meter, which will cause a 1 hour “snooze” until the FL0 message is displayed
again.
1
Seeker D internal memory is full. Shows at power-on if there is not enough room
for at least an 8-hour day’s worth of data (30,000 records). Shows at sync time if
there is not enough room to store the MCA III contents in the meter memory.
2
Seeker D “snapshot” memory is full - needs to be cleared with Seeker Setup or
docked to transfer snapshots to an MCA III.