4. Wire the DC power cables to the vehicle battery and an ignition-switched power source,
and then connect the cable to the back of the Seeker D Mobile Mount. The DC power
cable should be wired as follows:
• Red wire MUST be wired to the positive (+) battery terminal.
• White wire MUST be wired to an ignition-switched power source in order to allow
the Seeker MCA III to determine when the vehicle is turned OFF.
• Both black wires should be wired to ground or the negative (-) battery terminal.
• The provided in-line fuse holders MUST be wired in series between the end of
the red and black DC power cables and the vehicle battery to provide protection
to the Seeker D Mobile Mount.