35
Symptom
Possible causes
Corrective action
Effluent odour
directly outside the
house or inside the
house
Pipe connections to toilets /
drains not connected correctly.
Check that the traps / U - bends in the drains are
fitted and the joints sealed
Air vent on pipe work not fitted
or fitted incorrectly
Ensure all effluent pipes are vented correctly, vents
are normally fitted to all pipes and they should be
higher that the eve of the roof.
Pipe work is damaged or
blocked or fitted incorrectly
Inspect pipe work to ensure it is undamaged and clear
of obstructions or sagging.
Bad effluent odour
directly over the
tank
Pipe work to or from the tank is
blocked
Check the level of liquid in the tank. Ensure the pipes
are not blocked and are fitted correctly to the tank.
Chemical kill of bacteria
Ensure pumps are working properly if applicable. If
symptom persists for 48 hours or more, remove all
liquid and replace with clean water
No air delivery
Check blower is functioning properly
Hydraulic/Organic overloading
Reduce flow and/or organic load
Tank vent blocked
Clear tank vents