34
Blowers runs
intermittently
Thermal overload tripped
Protect installation from the sun.
Air supply vent blocked, clean if necessary
Filter blocked, replace if necessary
Discharge hose blocked or kinked, remove obstruction
Electrical fault
Get a qualified person to check that the alarm is
installed correctly and the power supply to the plant is
correct
Pump runs
intermittently
Thermal overload tripped
Check for clogged impeller
The pump has run dry so add water. Ensure the pump is
plugged out before you attempt to unclog it.
Float from the pump stuck
Ensure the float on the pump is set correct and can
move freely.
Damaged float
Pump must be checked by a qualified person
Plant fills above
working water
level
Subsurface disposal system
clogged
Contact installer to repair sub surface disposal system/
Percolation area.
Storm water flooding
Redirect storm water drains. Storm water must never
enter the system
Pump not working
Check pump is functioning properly as above
Discharge hose/pipe blocked
Find blockage and remove or replace damaged
hose/pipe
Alarm is sounding
but the pump and
blower are working
Air return pipe to the alarm
not returning an air signal.
Check that the air pipe is not damaged or bent. Ensure
there is air blowing through this pipe. Check that the
pipe is inserted to the alarm correctly.
Electrical fault.
Get a qualified person to check that the alarm is
installed correctly.
The electrical panel is wet
Get a qualified person to check that the alarm is
installed correctly.
Please Note:
Before taking any corrective action, always positively identify the real source of the odour. Check if the odour is
coming from another outside source such as a storm drain. All wastewater disposal plants vent gases back
through soil pipe and out roof vents. Improperly installed roof vents can cause odour problems. Traps in drains
prevent odours from entering the home. To function they must contain water and be sealed correctly.
Summary of Contents for NOVO EN6-50
Page 1: ...Technical Installation Manual Tricel Wastewater treatment systems TTM T106 Rev 06 Nov 13...
Page 11: ...11 Tricel Novo UK12 gravity plant Tricel Novo UK18 gravity plant...
Page 13: ...13 Tricel NovoUK42 gravity plant 2 tank plant...
Page 14: ...14 Tricel Novo UK50 gravity plant 2 tank plant Example of stepped installation...
Page 39: ...39...