9
Design population
UK36 *
UK42*
UK50*
Plant A
Plant B
Plant A
Plant B Plant A
Plant B
Nominal inlet/outlet pipe diameter mm
150
150
150
150
150
150
Overall length
m
2.6
5.6
3.6
5.6
3.6
6.6
Overall width
m
1.64
1.64
1.64
1.64
1.64
1.64
Overall height
m
1.99
2.27
1.99
2.27
1.99
2.27
Inlet invert to base
m
1.35
1.35
1.35
1.35
1.35
1.35
Outlet invert to base
m
1.3
1.3
1.3
1.3
1.3
1.3
Inlet invert to ground level
m
0.46
0.56
0.46
0.56
0.46
0.56
Outlet Invert to ground level
m
0.51
0.61
0.51
0.61
0.51
0.61
Height above ground level
m
0.18
0.36
0.18
0.36
0.18
0.36
Weight empty**
kg
300
600
400
600
400
700
BOD load
kg/day
2.16
2.52
3
Air blower rating (mean)
watts
200+80
200 x 2
200 x 2
Desludge period (minimum)***
months 12
12
12
Thickness (minimum)
mm
5
5
5
Retention time
hours
56.5
54.6
51.1
*Plants may require a stepped foundation, with “Tank B” lower than “Tank A” by 100mm approx.
** Allow 100kgs for lifting purposes
*** Depending on use
Summary of Contents for NOVO EN6-50
Page 1: ...Technical Installation Manual Tricel Wastewater treatment systems TTM T106 Rev 06 Nov 13...
Page 11: ...11 Tricel Novo UK12 gravity plant Tricel Novo UK18 gravity plant...
Page 13: ...13 Tricel NovoUK42 gravity plant 2 tank plant...
Page 14: ...14 Tricel Novo UK50 gravity plant 2 tank plant Example of stepped installation...
Page 39: ...39...