Grease Trap:
Best practice indicates that a grease trap be fitted before the plant particularly in applications where high
quantities of grease exist in the wastewater.
Sampling chamber:
Best practice indicates that a chamber be fitted after every unit to allow easy access for sampling purposes. The
inlet of the chamber must be higher than the outlet to facilitate sampling cup.
1. Ancillary installation notes:
The finished ground level should never be higher than the level indicated on the plant. A riser should be fitted if
required, see section 9.
13.1 Ventilation:
Ventilation is crucial to the plant and should be installed as per the building regulations
.
13.2 Control housings:
Monitoring equipment, alarms, blowers or pumps if supplied, may be placed into separate control housing.
These can be fitted with visual / audio / alarms along with other equipment. If so, a mains supply may be
required. Mains must be disconnected before maintaining the plant. Consideration should be given to the
location and security of the control housing.