Should the plant be used intermittently or if extended periods of non-use are expected, it is
recommended that the plant remain on and in operation. The contents of the plant should not be allowed
to go septic due to non-use.
•
The tank is not suitable for vehicular traffic. We also recommend fencing off the area to prevent
livestock herds from accessing the plant. Where possible, unnecessary human traffic around the
plant should be avoided.
Terms & conditions
Subject to our standard terms and conditions, which are available on request.
1. Troubleshooting:
Properly installed, operated and maintained plants will give many years of trouble free service. All plants are
fitted with an alarm, which will alert of irregularities in the plant. If a blower or pump stops working a buzzer will
sound to indicate there is a problem with the plant. The buzzer can be muted until the problem is fixed. Once
fixed, the alarm will reset automatically and the mute switch must be turned on. All electrical work shall be
carried out by a qualified person.
Symptom
Possible causes
Corrective action
Blower/Pump
won’t start or run
Fuse blown (if applicable)
Replace with fuse of proper size
Tripped breaker
Reset breaker
Low line voltage and wet
electrics
An electrician should check the power supply to the
plant
Defective blower/pump
Blower/pump must be checked by a qualified person
Blower operates
but delivers no air
Low line voltage
An electrician should check the power supply to the
plant
Filter blocked
Replace filter
Diaphragm broken
Replace diaphragm if applicable
Defective blower malfunction Air blower must be checked by a qualified person
Pump operates but
delivers no water
Low line voltage
An electrician should check the power supply to the
plant
Something caught in impellers Clean out impellers or replace pump. Ensure pump is
disconnected from the mains before you attempt to
unclog it.
Delivery hose blocked
Find blockage and remove or replace damaged hose
Other pump malfunction
Pump must be checked by a qualified person
Summary of Contents for NOVO EN6-50
Page 1: ...Technical Installation Manual Tricel Wastewater treatment systems TTM T106 Rev 06 Nov 13...
Page 11: ...11 Tricel Novo UK12 gravity plant Tricel Novo UK18 gravity plant...
Page 13: ...13 Tricel NovoUK42 gravity plant 2 tank plant...
Page 14: ...14 Tricel Novo UK50 gravity plant 2 tank plant Example of stepped installation...
Page 39: ...39...