41
Scanner Resolution
is used to determine the size of the message in inches. This value is based on
the type of scanner, focusing optics and the distance from the scanner to the wire.
Laser Com Port
specifies computer serial port numbers for laser connections.
Local IP Address
is the IP address of the supplied computer.
PLC IP Address
is the IP address of the PLC.
Printer IP Address and port
relate to the optional label printers.
Warm Up Time
is the amount of time after the diode is turned on before the laser is ready. The
diode turns on automatically when the machine powers up.
Conversion Factor
is used to convert the analog input from the laser power meter to Watts.
Laser Off Time
is the maximum time the laser can be idle before turning the diode pump off.
Click the
Save
button to save all these values to the application.
Click the
Cancel
button to close the dialog box without saving any changes