Installation
(for qualified installers only)
15
© Travis Industries
4101028
100-01255_000
Approved Vent Configurations
Exhaust Restrictor Position
•
An exhaust restrictor is built into the appliance to control the flow rate of exhaust gases. This
ensures proper flames for the wide variety of vent configurations. Depending upon the vent
configuration, you may be required to adjust the restrictor position. The charts for approved vent
configurations describe which position the vent restrictor should be in.
NOTE:
If the vent configuration calls for restrictor removal, replace the screws into the holes
in the firebox ceiling to seal the firebox.
Loosen these two screws
on the exhaust restrictor.
Slide the restrictor to the correct
restrictor position (see the illustration
below). The screw location indicates
restrictor position. In this example, the
restrictor is set in position # 3. Tighten
the screws to secure the restrictor.
(closed) # 5
# 4
# 3
# 2
(open - stock position) # 1
Back Wall of Firebo
x
Firebo
x Roof