Clearances
Due to the high temperature of the heater, it should be located out of traffic and away from furniture and
draperies.
Minimum
Clearances
k Sidewall to Insert
5" (127mm)
l
Side Facing
(non-combustible)
3-3/8 " (86mm)
m Top Facing*
(non-combustible)
32-3/8" (823mm)
n 12”
Mantel*
(combustible
or non-combustible)
34-1/2" (877mm)
n 4” Mantel* (combustible
or non-combustible)
33-1/2" (851mm)
p Hearth Extension to the
Front of Insert
0" (0mm)
x Extension onto Hearth
1 Piece Panel
1 Piece Panel
w/Trim Kit
0" (0mm)
1-1/4” (32mm)
* Measured from the base of the insert.
NOTE
: the non-combustible top facing must extend
32-3/8” (823mm) above the base of the insert or to
the bottom of the mantel (whichever is less).
Mantel Clearances
The maximum mantel depth is 12” (305mm).
NOTE:
The combustible area above the facing must not protrude more than 3/4" (20mm) from the facing.
If it does, it is considered a mantel and must meet the mantel requirements listed in this manual.
Side
Wall
Com
bust
ible o
r No
n-C
om
bust
ible M
ante
l
Com
bust
ible T
op F
acin
g
No
n-C
om
bust
ible
Faci
ng
l
k
x
n
m
p
IDB1007
Mantel Height
Above B as e of Ins ert (n)
34"(864mm)
33"(839mm)
32"(813mm)
31"(788mm)
35"(889mm)
0" 1"
(
26m
m
)
2"
(
51m
m)
8"
(
204m
m)
7
" (178
m
m
)
6"
(
153m
m
)
5"
(
127m
m
)
4"
(
102m
m
)
3
" (77
m
m
)
9"
(
229m
m)
10"
(
254m
m
)
11
"
(280m
m
)
12"
(
305m
m)
Maximum Mantel Depth