Co-Linear to Co-Axial Pipe
DuraVent manufactures a vent kit that adapts flexible co-linear venting to co-axial pipe. This can be
helpful for situations such as when a damaged masonry chimney top is removed to below the roofline or
when an additional story is added to a home and the added height covers the existing masonry chimney
height. The DuraVent kits (46DVA-CLTA and 46DVA-34CLTA) are approved for use with Travis
Industries gas inserts.
These kits can be purchased from your DuraVent dealer.
Application
DuraVent Part #
DuraVent Stock #
For inserts that use 3” exhaust and 3” intake
46DVA-CLTA
810014742
For inserts that use 3” exhaust and 4” intake
46DVA-34CLTA
810014340
Max. 40’
(12.2M)
- Check with the local
Authority Having
Jurisdiction before
installing in this manner.
- The fireplace must be
permanently marked to
indicate that it has been
altered and no longer
suitable for burning solid
fuel (wood).
- All additional
requirements in the
manual for the installation
must be met.
- Refer to the vent
manufacturer’s
instructions for further
details.