42
Maintenance
© Travis Industries
9/22/2020 - 1521
430 EG GSR2
Wiring Diagram
CAUTION
: Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation.
Replacement Parts
Caution:
Use only Travis Industries replacement parts. Do not use substitute materials.
Warning:
Do not operate appliance with the glass front removed, cracked, or broken. Replacement of
the glass should be done by a licensed or qualified service person.
Contact your local Travis Industries Dealer for a Replacement Parts List
3.15A
FUSE
O
ran
ge
Ye
llo
w
System
Jumper
Pu
rp
le
Gr
e
y
Spark
Rod
Comfort Control
Valve
Battery Box
(Manual On/Off)
Accent
Light (s)
Blower(s)*
3 Amp
Fuse
Appliance
Ground
Gr
e
en
Or
an
ge
Ye
llo
w
/
G
re
en
Wh
ite
Bl
ue
IPI/CPI
JUMPER WIRE
Bl
ue
Pi
nk
Power
In
TO
P
(4) AA Batteries
Bl
ac
k
Re
d
Ye
llo
w
Or
an
g
e
Ye
llo
w
Flame
Detect
Black
Red
Pu
rp
le
Gr
ey
Wh
ite
Wh
ite
Bl
ac
k
3 Amp
Fuse
EmberBed
Lights*
Rheostat
3 Amp
Fuse
Integrated Fireplace Control (IFC)
Bl
ac
k
Black
White
May Include
Molex
May Include
Molex