U
SING THE
D
IRECT
F
UNCTIONS
Page 16
CineMonitor
HD
Evolution
Measurements
Short push on
Measure
–
toggles the different views of the selected measurement
Long push on Measure to select the measurement to display.
The brightness of the reticule and of the spot as well as the background transparency in overlay
mode (for waveform and vectoscope) can be adjusted in MENU / TOOLS / MEASUREMENT.
White and black clipping alert can be configured in MENU / TOOLS / LIMITS. The same limits are
used for the waveform and the histogram. Setting these limits is useful to have a visual alert on the
measurement tools if there is a risk of overexposure or of loss of black details.
Waveform
Long push on
Measure
– measurement selection
Selecting "F1: WAVE" gives access to the selection of the waveform modes.
Press F1 to display the waveform in line mode
Press F2 to display the waveform in parade mode
Press F3 to display the waveform in frame mode
Press rotating knob to exit from menu.
Then a short push on Measure toggles the different views of the selected waveform mode (if any).
It also gives the possibility to adjust the size of the waveform by using the rotating knob (3 sizes
available)
LINE
Displays one single spot (Y, Red, Green or Blue)
PARADE
Displays Y, R, G, B, Cr & Cb in parade mode.
Available modes: YRGB / YGBR / RGB / GBR / YCrCb
FRAME
Displays Y, R, G, B in frame mode (or sweep mode).
The content of one frame/picture is displayed.