TT100
·
75
·
B
asic Par
ame
te
rs
F144 User-defined frequency point 3
F142
~
F146
10.00
╳
F145 User-defined voltage point 3
0
~
100
%
24
╳
F146 User-defined frequency point 4
F144
~
F148
20.00
╳
F147 User-defined voltage point 4
0
~
100
%
45
╳
F148 User-defined frequency point 5
F146
~
F150
30.00
╳
F149 User-defined voltage point 5
0
~
100
%
63
╳
F150 User-defined frequency point 6
F148
~
F118
40.00
╳
F151 User-defined voltage point 6
0
~
100
%
81
╳
F152
Output voltage corresponding to
turnover frequency
10
~
100
%
100
╳
F153 Carrier frequency setting
0.2
~
7.5KW: 2
~
10K
4K
╳
11
~
15KW: 2
~
10K
3K
18.5KW
~
45KW: 2
~
6K
4K
Above 55KW: 2
~
4K
2K
F154 Automatic voltage rectification
0: Invalid 1: Valid
2:Invalid during deceleration
process
0
╳
F155 Digital accessorial frequency setting
0
~
F111
0
╳
F156
Digital accessorial frequency polarity
setting
0 or 1
0
╳
F157 Reading accessorial frequency
△
F158
Reading
accessorial
frequency
polarity
△
F159
Random carrier-wave frequency
selection
0: Control speed normally;
1: Random carrier-wave frequency
1
F160 Reverting to manufacturer values
0: Not reverting to manufacturer values;
1: Reverting to manufacturer values
0
╳
R
un
ni
ng
C
o
ntr
ol
Mod
e
F200 Source of start command
0: Keypad command;
1: Terminal command;
2: Keypad
+
Terminal;
3:MODBUS; 4: Keypad
+
Terminal
+
MODBUS
0
╳
F201 Source of stop command
0: Keypad command;
1: Terminal command;
2: Keypad
+
Terminal;
3:MODBUS; 4: Keypad
+
Terminal
+
MODBUS
0
╳
F202 Mode of direction setting
0: Forward running locking;
1: Reverse running locking;
2: Terminal setting
0
╳