carrier-wave set by F153 is selected, nosie will be reduced, but output torque will decrease. Please set the value
according to the situation.
F160 Reverting to manufacturer values
Setting range:
0: Not reverting to manufacturer values;
1: Reverting to manufacturer values
Mfr‟s value: 0
·When there is disorder with inverter‟s parameters and manufacturer values need to be restored, set F160=1.
After “Reverting to manufacturer values” is done, F160 values will be automatically changed to 0.
· “Reverting to manufacturer values” will not work for the function-codes marked “○”in the “change”
column of the parameters table. These function codes have been adjusted properly before delivery. And it is
recommended not to change them.
Figure 5-3 Reverting to manufacturer values
▲
1
set
0
▼
F 1 6 0
F 1 0 0
OK!
10
set