TT100
·
11
·
III.
Installation & Connection
3.1
Installation
Inverter should be installed vertically, as shown in Fig 3-1. Sufficient ventilation space should be ensured in
its surrounding. Clearance dimensions (recommended) are available from Table 3-1 for installing the
inverter.
Table 3-1
Clearance Dimensions
Inverter Model
Clearance Dimensions
Hanging (≤ 15 kw)
A≥150mm
B≥50mm
3.2
Connection
In case of 3-phase input, connect R/L1,
S/L2 and T/L3 terminals (L1/R and
L2/S terminals for single-phase) with
power source from network and
/PE/E to earthing, U, V and W terminals to motor.
Motor shall have to be ground connected. Orelse electrified motor causes interference.
For inverter power lower than 15kw, braking cell is also built-in. If the load inertia is moderate,
it is Ok to only connect braking resistance.
Power terminals sketch of inverter with single-phase 230V 0.2~0.75KW.
L1
L2
P
B
U
V
W
Power terminals sketch of inverter with single-phase 230V 1.5~2.2KW and three-phase
400V 0.75KW~15KW.
L1/R L2/S L3/T
P
-
B
U
V
W
Note: power terminals L1/R, L2/S of single-phase 230V 1.5KW and 2.2KW are connected
to 230V of power grid; L3/T is not connected.
The inverters below 11kw have no the terminal “
-
”.
Grounding
Input ~400V
For braking resistor
Output
Grounding Input ~230V For braking resistor
Output
A
B B
A
In
v
er
ter
C
D D
In
v
er
ter
Trench
Hanging
Cabinet
Fig 3-1 Installation Sketch