Transition Networks
SM24DP4XA Install Guide
33769 Rev. A
Page
15
of
42
4. AC 240V Input
Status
Test Status
AC Voltage
(V)
AC Current
Consumption
(A)
Power
Factor
Apparent
Power (VA)
Real Power
(W)
No Loading
None
240
0.19
0.44
45.60
20.06
Full-load 5 minutes
20-Port 1G SFP
4-Port 1G RJ45
4-Port 10G SFP
240
0.36
0.45
86.40
38.88
Full-loading
60 minutes later
20-Port 1G SFP
4-Port 1G RJ45
4-Port 10G SFP
240
0.39
0.45
93.60
42.12
Status
Test Status
AC Voltage
(V)
AC Current
Consumption
(A)
Power
Factor
Apparent
Power (VA)
Real Power
(W)
Full-load 5 minutes
22-Port 1G SFP
2-Port 1G RJ45
4-Port 10G SFP
240
0.36
0.45
86.40
38.88
Full-loading
60 minutes later
22-Port 1G SFP
2-Port 1G RJ45
4-Port 10G SFP
240
0.39
0.45
93.60
42.12
Status
Test Status
AC Voltage
(V)
AC Current
Consumption
(A)
Power
Factor
Apparent
Power (VA)
Real Power
(W)
Full-load 5 minutes
24-Port 1G SFP
4-Port 10G SFP
240
0.35
0.45
84.00
37.80
Full-loading
60 minutes later
24-Port 1G SFP
4-Port 10G SFP
240
0.38
0.45
91.20
41.04
Note
: Apparent Power (VA) = AC Voltage x AC Current Consumption.
Real Power (W) = Apparent Power (VA) x Power Factor.