Transition Networks
SM24DP4XA Install Guide
33769 Rev. A
Page
14
of
42
3. AC 220V Input
Status
Test Status
AC Voltage
(V)
AC Current
Consumption
(A)
Power
Factor
Apparent
Power (VA)
Real Power
(W)
No Loading
None
220
0.20
0.45
44.00
19.80
Full-load 5 minutes
20-Port 1G SFP
4-Port 1G RJ45
4-Port 10G SFP
220
0.37
0.46
81.40
37.44
Full-loading
60 minutes later
20-Port 1G SFP
4-Port 1G RJ45
4-Port 10G SFP
220
0.41
0.46
90.20
41.49
Status
Test Status
AC Voltage
(V)
AC Current
Consumption
(A)
Power
Factor
Apparent
Power (VA)
Real Power
(W)
Full-load 5 minutes
22-Port 1G SFP
2-Port 1G RJ45
4-Port 10G SFP
220
0.38
0.46
83.60
38.46
Full-loading
60 minutes later
22-Port 1G SFP
2-Port 1G RJ45
4-Port 10G SFP
220
0.41
0.46
90.20
41.49
Status
Test Status
AC Voltage
(V)
AC Current
Consumption
(A)
Power
Factor
Apparent
Power (VA)
Real Power
(W)
Full-load 5 minutes
24-Port 1G SFP
4-Port 10G SFP
220
0.38
0.46
83.60
38.46
Full-loading
60 minutes later
24-Port 1G SFP
4-Port 10G SFP
220
0.41
0.46
90.20
41.49
Note
: Apparent Power (VA) = AC Voltage x AC Current Consumption
Real Power (W) = Apparent Power (VA) x Power Factor