RTAA-SVX01A-EN
9
General Information
Model Number Coding System
The model number for the unit is comprised of numbers and letters which
represent features of the equipment. Shown on the chart in
Figure 3
are
samples of typical unit model numbers, followed by the coding system.
Each position, or group of positions, in the number is used to represent a
feature. For example, in
Figure 3
, position 8 of the unit model number, Unit
Voltage, contains the number “4”. From the chart, it can be seen that a “4” in
this position means that the unit voltage is 460/60/3.
.
Figure 3
Model Number Coding System:
Model Number
RTA
A
070
4
Y
A0
1
B
1
D
A
0
Digit Number
0
1
2
Digit Position
1 2 3
4
5 6 7
8
9
0 1
2
3
4
5
6
0
D
igi
t 1-2
Un
i
t Model
RT
Rotary Chiller
D
igi
t 3
Un
i
t Ty
p
e
A
Air Cooled
D
igi
t
4
Develo
p
ment Se
q
uen
c
e
A
First Sequence
D
igi
t 5,6,7
Nom
i
n
a
l C
apaci
ty
070
70 No
m
inal Tons
0
8
0
8
0 No
m
inal Tons
090
90 No
m
inal Tons
100
100 No
m
inal Tons
110
110 No
m
inal Tons
125
125 No
m
inal Tons
D
igi
t
8
Un
i
t Volt
ag
e
D
3
8
0/60/3
A
200/60/3
C
230/60/3
K
400/50/3
4
460/60/3
5
575/60/3
D
igi
t 9
Com
p
ressor St
a
rter Ty
p
e
Y
Y -Delta Closed Transition
X
X-Line (Across the Line)
D
igi
t 10, 11
Des
ig
n Se
q
uen
c
e
AO
First Sequence (Factory Input)
D
igi
t12
Ev
ap
or
a
tor Le
a
v
i
n
g
Tem
p
er
a
ture
1
Standard 40 to 65 F
2
Low 0 to 39 F
3
Ice-Making 20 to 65 F
D
igi
t 13
Condenser Co
i
l F
i
n M
a
ter
ia
l
A
Alu
m
inu
m
2
Co
m
pleteCoat dipped coils
4
copper fins
D
igi
t 1
4
A
g
en
c
y L
i
st
i
n
g
0
No Agency Listing
3
C-UL Listed
D
igi
t 15
Control Interf
ac
e
C
Deluxe without Co
mm
unication
D
Deluxe with Co
mm
unication
L
LCI-C (LonTalk)
D
igi
t 16
Ch
i
lled W
a
ter Reset
0
No Chilled
W
ater Reset
1
Based on Return
W
ater Te
m
p
2
Based on Outside Air Te
m
p
D
igi
t 17
M
i
s
c
ell
a
neous F
ac
tory Inst
a
lled
O
p
t
i
ons
A
Architectural Louvered Panels
B
Control Power Transfor
m
er
C
Convenience Outlet
D
Low A
m
bient Lockout Sensor
F
Power Disconnect
G
Low A
m
bient Operation
H Sound
Attenuator
J
Re
m
ote Evaporator
K
Coil Protection
M
Access Guard
N
Neoprene Isolators
P
Circuit Breaker
R
Re
m
ote Display Panel
0
Size C 2 HP Pu
m
p Package
1
Size D 3 HP Pu
m
p Package
2
Size D 5 HP Pu
m
p Package
3
Size E 2 HP Pu
m
p Package
4
Size E 3 HP Pu
m
p Package
5
Size F 5 HP Pu
m
p Package
6
Size F 7 HP Pu
m
p Package
7
Size G 3 HP Pu
m
p Package
8
Size G 5 HP Pu
m
p Package
Summary of Contents for RTAA-100
Page 110: ...110 RTAA SVX01A EN Start Up Procedures Figure 37 Unit Sequence of Operation...
Page 143: ...RTAA SVX01A EN 143 Pump Package Figure 47 Pump Package Piping Schematic...
Page 144: ...144 RTAA SVX01A EN Pump Package...
Page 146: ...146 RTAA SVX01A EN 3327...
Page 147: ...RTAA SVX01A EN 147...
Page 148: ...148 RTAA SVX01A EN 3328...
Page 149: ...RTAA SVX01A EN 149...
Page 150: ...150 RTAA SVX01A EN 6516...
Page 151: ...RTAA SVX01A EN 151...
Page 152: ...152 RTAA SVX01A EN 3329...
Page 153: ...RTAA SVX01A EN 153...
Page 154: ...154 RTAA SVX01A EN 6472...
Page 155: ...RTAA SVX01A EN 155...
Page 156: ...RTAA SVX01A EN 156 3330...
Page 157: ...157 RTAA SVX01A EN...
Page 158: ...158 RTAA SVX01A EN 6046...
Page 159: ...RTAA SVX01A EN 159...
Page 160: ...160 RTAA SVX01A EN 3331...
Page 161: ...RTAA SVX01A EN 161...
Page 162: ...162 RTAA SVX01A EN 6519...
Page 163: ...RTAA SVX01A EN 163...
Page 164: ...164 RTAA SVX01A EN 6047...
Page 165: ...RTAA SVX01A EN 165...
Page 166: ...166 RTAA SVX01A EN 3325...
Page 167: ...RTAA SVX01A EN 167...
Page 168: ...168 RTAA SVX01A EN 6048...
Page 169: ...RTAA SVX01A EN 169...
Page 172: ...172 RTAA SVX01A EN 3326...
Page 173: ...RTAA SVX01A EN 173...
Page 174: ...174 RTAA SVX01A EN 6049...
Page 175: ...RTAA SVX01A EN 175...
Page 176: ...176 RTAA SVX01A EN 6463...
Page 177: ......