Model Number Description
All Trane products are identified by a multiple-character
model number that precisely identifies a particular type of
unit. An explanation of the alphanumeric identification code
is provided below. Its use will enable the owner/operator, in-
stalling contractors, and service engineers to define the op-
eration, specific components, and other options for any spe-
cific unit.
When ordering replacement parts or requesting service, be
sure to refer to the specific model number, serial number,
and DL number (if applicable) stamped on the unit name-
plate.
Unit Nameplate
One Mylar unit nameplate is located on the outside upper
right corner of the control panel door. It includes the unit
model number, serial number, electrical characteristics,
weight, refrigerant charge, as well as other pertinent unit
data. A small metal nameplate with the Model Number, Se-
rial Number, and Unit Weight is located just above the Mylar
nameplate, and a third nameplate is located on the inside of
the control panel door.
When ordering replacement parts or requesting service, be
sure to refer to the specific model number, serial number,
and DL number (if applicable) stamped on the unit name-
plate.
Compressor Nameplate
The nameplate for the “Scroll” compressors are located on
the compressor lower housing.
Evaporator Barrel Nameplate
(EVP Chiller Applications Only)
The nameplate is located on the top of the evaporator near
the supply-end tube sheet. The word “Nameplate” is sten-
ciled on the insulation. To view the nameplate, remove the
tape over the area and spread the insulation. Retape the in-
sulation after viewing.
Sample
Model No.: RAUC - C80 4 A B 1 1 2 H, B, 3, etc
Digit No.: 1 2 3 4 5,6,7 8 9 10 11 12 13 14+
Digit 1 - Unit Type
Digit 8 - Power Supply
Digit 12 - Agency Approval
R = Remote Condensing Unit
E = 200/60/3 XL
0 = None
F = 230/60/3 XL
3 = UL/CSA
Digit 2 - Condenser
4 = 460/60/3 XL
A = Air Cooled
5 = 575/60/3 XL
Digit 13 - Number of Circuits
2 = Dual Circuit
Digit 3 - Air Flow
Digit 9 - System Control
U = Up Flow
B = No System Control
Digits 14, etc. - Miscellaneous Options
E = Supply Air VAV Control
Digit 4 - Development Sequence
P = EVP Control
1 = Spring Isolators
C = Third
3 = Flow Switch (EVP Only)
Digit 10 - Design Sequence
9 = Packed Stock
Digits 5, 6, 7 - Nominal Capacity
L = Disconnect Redesign
B = Hot Gas Bypass Valves
C80 = 80 Tons
D = Suction Service Valves
D10 = 100 Tons
Digit 11 - Ambient Control
F = Pressures Gauges & Gauge Piping
D12 = 120 Tons
0 = Standard
H = Copper Fins
1 = 0 F
Hazard Identification
Warnings are provided through-
out this manual to indicate to installing contractors, opera-
tors, and service personnel of potentially hazardous situa-
tions which, if not avoided, COULD result in death or seri-
ous injury.
Cautions are provided throughout
this manual to indicate to installing contractors, operators,
and service personnel of potentially hazardous situations
which, if not avoided, MAY result in minor or moderate in-
jury.
Unit Description
All air cooled condensing units are designed for outdoor in-
stallations with vertical air discharge. These units may be
installed on a flat roof or placed on a concrete slab at
ground level.
Before shipment, each unit is leak-tested, evacuated, a Ni-
trogen holding charge is added, and the controls are tested
for proper operation.
The condenser coils are aluminum fin, bonded to copper
tubing. Copper-fin coils are optional. Louvered condenser
grilles for coil protection are standard.
General Information
Summary of Contents for RAUC-IOM-15
Page 8: ...8 Figure 3 2A RAUC C80 Unit Dimensional Data Recommended Clearances...
Page 9: ...9 Figure 3 2A Continued RAUC D10 Unit Dimensional Data Recommended Clearances...
Page 10: ...10 Figure 3 2A Continued RAUC D12 Unit Dimensional Data Recommended Clearances...
Page 11: ...11 Figure 3 2B EVPB C80 Evaporator Chiller Dimensions...
Page 12: ...12 Figure 3 2B Continued EVPB D10 Evaporator Chiller Dimensions...
Page 13: ...13 Figure 3 2B Continued EVPB D12 Evaporator Chiller Dimensions...
Page 14: ...14 Figure 3 2B Continued EVPB C80 through D12 Chill Water Pipe Stubout Dimensions...
Page 35: ...35 Installation Continued Field Connection Diagram Notes for all System Control Options...
Page 57: ...57 Figure 5 5 Typical Scroll Compressor Terminal Block System Start Up Continued...
Page 67: ...67...
Page 68: ...68...