LPC-SVX01C-EN
13
Installation
general
information
Digit 34 – Cooling control valve options
0 = none
A =
3
/
4
” 2-way, NO 7.3 Cv
B =
3
/
4
” 2-way, NC 7.3 Cv
C =
3
/
4
” 3-way, NO 7.3 Cv
D =
3
/
4
” 3-way, NC 7.3 Cv
E = 1” 2-way, NO 11.6 Cv
F = 1” 2-way, NC 11.6 Cv
G = 1” 3-way, NO 11.6 Cv
H = 1” 3-way, NC 11.6 Cv
J = 1
1
/
4
” 2-way, NO 18.5 Cv
K = 1
1
/
4
” 2-way, NC 18.5 Cv
L = 1
1
/
4
” 3-way, NO 18.5 Cv
M = 1
1
/
4
” 3-way, NC 18.5 Cv
N = 1
1
/
2
” 2-way, NO 28.9 Cv
P = 1
1
/
2
” 2-way, NC 28.9 Cv
Q = 1
1
/
2
” 3-way, NO 28.9 Cv
R =1
1
/
2
” 3-way, NC 28.9 Cv
T = 2” 2-way, NO 46.2 Cv
U = 2” 2-way, NC 46.2 Cv
V = 2” 3-way, NO 46.2 Cv
W = 2” 3-way, NC 46.2 Cv
X = 2
1
/
2
” 2-way, NO 54 Cv
Y = 2
1
/
2
” 2-way, NC 54 Cv
Z = 2
1
/
2
” 3-way, NO 54 Cv
1 = 2
1
/
2
” 3-way, NC 54 Cv
2 = field supplied, 2-way NO
3 = field supplied, 2-way NC
6 = field supplied, 3-way NC
7 = field supplied, 3-way NC
Note: NO = Normally open & NC = Normally closed in the
valve’s de-energized state
Digit 35 – Reheat control valve options
0 = none
A =
3
/
4
” 2-way, NO 7.3 Cv
B =
3
/
4
” 2-way, NC 7.3 Cv
C =
3
/
4
” 3-way, NO 7.3 Cv
D =
3
/
4
” 3-way, NC 7.3 Cv
E = 1” 2-way, NO 11.6 Cv
F = 1” 2-way, NC 11.6 Cv
G = 1” 3-way, NO 11.6 Cv
H = 1” 3-way, NC 11.6 Cv
J = 1
1
/
4
” 2-way, NO 18.5 Cv
K = 1
1
/
4
” 2-way, NC 18.5 Cv
L = 1
1
/
4
” 3-way, NO 18.5 Cv
M = 1
1
/
4
” 3-way, NC 18.5 Cv
N = 1
1
/
2
” 2-way, NO 28.9 Cv
P = 1
1
/
2
” 2-way, NC 28.9 Cv
Q = 1
1
/
2
”3-way, NO 28.9 Cv
R = 1
1
/
2
” 3-way, NC 28.9 Cv
T = 2” 2-way, NO 46.2 Cv
U = 2” 2-way, NC 46.2 Cv
V = 2” 3-way, NO 46.2 Cv
W = 2” 3-way, NC 46.2 Cv
X = 2
1
/
2
” 2-way, NO 54 Cv
Y = 2
1
/
2
” 2-way, NC 54 Cv
Z = 2
1
/
2
” 3-way, NO 54 Cv
1 = 2
1
/
2
” 3-way, NC 54 Cv
2 = field supplied, 2-way NO
3 = field supplied, 2-way NC
6 = field supplied 3-way NO
7 = field supplied 3-way NC
Note: NO = Normally open & NC = Normally closed in the
valve’s de-energized state
Digit 36 – External exhaust fan support
0 = none
1 = configure for control
2 = configure for exhaust fan start/stop &
status support
3 = generic temperature thermistor
Digit 37 – Zone sensor options
0 = none
1 = sensor w/off, auto, Fahrenheit knob,
on/cancel and comm jack
2 = sensor w/Fahrenheit knob, on/cancel
and comm jack
4 = sensor only
5 = field supplied zone sensor
F = standalone operator display
G = 1 & F
H = 2 & F
J = 4 & F
K = 5 & F
Summary of Contents for LPC
Page 50: ...50 LPC SVX01C EN Operation general information Figure O GI 9 Tracer AH540 termination board ...
Page 91: ...LPC SVX01C EN 91 Maintenance diagnostics Table M D 2 Tracer AH540 541 diagnostics ...
Page 92: ...92 LPC SVX01C EN Maintenance diagnostics Table M D 2 continued Tracer AH540 541 diagnostics ...
Page 94: ...94 LPC SVX01C EN Maintenance troubleshooting Table M T 2 Valves stay open ...
Page 95: ...LPC SVX01C EN 95 Maintenance troubleshooting Table M T 3 Valves stay closed ...
Page 96: ...96 LPC SVX01C EN Maintenance troubleshooting Table M T 4 Outdoor air damper stays open ...
Page 97: ...LPC SVX01C EN 97 Maintenance troubleshooting Table M T 5 Outdoor air damper stays closed ...
Page 107: ...LPC SVX01C EN 107 Maintenance appendix Table M A 6 Hard wired CO2 sensor values ...
Page 109: ......