Fitting the handwheel:
–
Remove the plug (3).
–
Take the handwheel (4) out of the bracket (5).
–
Fit the handwheel (4) in the motor shaft and then turn it until the pin latches into the slot in the motor shaft.
Operating with a single operator:
–
Use one hand to turn the handwheel (4) and simultaneously use the lever (1) to open the operating brake whilst the handwheel is
being turned.
The operating brake must be closed again before re-gripping and re-positioning the hand on the handwheel.
Operating with two operators:
–
Operator 1: Turn the handwheel (4) using both hands.
–
Operator 2: Use the lever (1) to open the operating brake whilst operator 1 is turning the handwheel.
The operating brake must be closed again before re-gripping and re-positioning the hand on the handwheel.
Removing the handwheel:
–
Pull the handwheel (4) out of the motor shaft and secure it in the special bracket (5).
DANGER!
Risk of being crushed! Risk of injury!
From the rotating motor shaft!
Risk of falling! Risk of being injured by falling objects!
Moisture can impair the effectiveness of the brake!
–
Replace the plug (3) after you have used the handwheel and check that it is seated correctly.