Interfaces of the function group Encoder-Basic
TR-Electronic GmbH 2013, All Rights Reserved
Printed in the Federal Republic of Germany
Page 94 of 103
TR - ECE - BA - DGB - 0105 - 03
08/31/2017
6.3.2 S-0-0601.0.01 Encoder data out configuration
The parameter
Encoder data out configuration
defines the parameter list provided for the
cyclical output. The data are output via parameter S-0-0600.0.20
Encoder data out container
see page 90.
Bit
Value
Description
Comments
15-8
reserved
7-0
Standard telegrams
0000 0010
Standard telegram 2
not supported
0000 0001
Standard telegram 1
not supported
0000 0000
Standard telegram 0
S-0-0600.0.2 Position not
S-0-0600.0.1 Encoder status
reserved
Parameter-Format, Encoder data out configuration
name
Encoder data out configuration
attribute length (octet)
2
data type and display format
binary
function
parameter
positions after decimal point
0
write protection
OL
conversion factor
1
scaling / resolution of LSB
1
unit
n/a
minimum value
n/a
maximum value
n/a
scope of parameter
local