TOSOT DC INVERTER U-MATCH AIR
61
1.2.2 Installation of Air Handler
Diagram of installation location and space for indoor unit (
Notice:
This air handler is designed for
indoor installation only. Do not install it outdoors).
(A) (B)
Figure 3-1-24
This air handler is designed for a complete supply and return ductwork system. Do not operate this
product without all ductwork attached.
Based upon the actual conditions, if air handler is installed as Fig 3-1-24 (A), the air handler should
be concealed in a specific room or space and make sure the air handler is not accessible to the general
public.
Based upon the actual conditions, if air handler is installed as Fig 3-1-24 (B), make sure that there is
enough space for care and maintenance and the height between the air handler and ground is above
2500mm. And the air handler is not accessible to the general public.
The water level test must be done after installing the indoor unit to make the unit is horizontal.
2 OUTDOOR UNIT INSTALLATION
2.1 Before Installation
After receiving the machine, please check for any transport damage. If finding any surface or
internal damage, please immediately report to the transport company or equipment company in writing.
After receiving the machine, please check the unit and accessories in reference to the packing list.
Ensure that the model is correct and the machine is in good condition. Please also check if the
specification and quantity of accessory parts are correct.
Determine the correct handling route and methods, thus to avoid damaging the unit or causing
possible hazard. For the sake of protection and safety, it is suggested to move the unit with the
packaging box. Even though it is not permitted to do like this under special occasions, do not remove the
packaging box, thus to
avoid loosening or falling during handling.
Confirm if the installing foundation is solid. When this unit is to be installed on the metal section of
the building, make sure that the electrical insulation must comply with applicable standards.
Ensure that the place of installation is far from the area where the inflammable or explosive
substances are stored, thus to avoid possible explosion or fire due to leakage.