3.31 SETUP
3 Tests and Diagnostics
TECRA M10 Maintenance Manual (960-685)
[CONFIDENTIAL]
3-89
Critical Battery Wake-up
Configures what action is taken when the remaining battery power is close to
running out while the system is in Sleep Mode.
This setting is only available when the Critical battery action in Windows is
set to Hibernate (Default).
To access it, Start -> Control Panel -> System and Maintenance ->
Power Options -> Edit Plan Settings -> Change advanced power settings ->
Battery.
The operation of this function is dependent upon battery status.
Enabled
When the remaining battery power is about to run out while
the system is in Sleep Mode, the system is automatically
woken up and then switched to Hibernation Mode
(Default).
Disabled
No action is taken even if the remaining battery power is
about to run out while the system is in Sleep Mode.
(g)
Beep Volume
This Option sets up the volume of a Beep sound.
Medium
→
High
→
OFF
→
Low
(h)
Diagnostic Mode
This option enables/disables the HW Diagnostic test function.
Enabled
Disables the HW Diagnostic test function. (Default)
Disabled
Enables the HW Diagnostic test function.
(i)
USB Sleep and charge
This Option sets up whether a power supply is supplied to a USB device,
when PC is in a Sleep mode state.
Disabled
A power supply is not supplied in a Sleep mode state.
(Default)
Enabled
(
Mode1
)
A power supply is supplied in a Sleep mode
state.
Enabled
(
Mode2
)
A power supply is supplied in a Sleep mode
state.
Enabled
(
Mode3
)
A power supply is supplied in a Sleep mode
state.
Enabled
(
Mode4
)
A power supply is supplied in a Sleep mode
state.
Summary of Contents for Tecra M10
Page 11: ... CONFIDENTIAL Chapter 1 Hardware Overview ...
Page 12: ...1 Hardware Overview 1 ii CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 ...
Page 46: ...1 Hardware Overview 1 10 AC Adapter 1 32 CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 ...
Page 47: ... CONFIDENTIAL Chapter 2 Troubleshooting Procedures ...
Page 48: ...2 Troubleshooting Procedures 2 ii CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 2 ...
Page 52: ...2 Troubleshooting Procedures 2 vi CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 ...
Page 123: ... CONFIDENTIAL Chapter 3 Tests and Diagnostics ...
Page 124: ...3 Tests and Diagnostics 3 ii CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 3 ...
Page 128: ...3 Tests and Diagnostics 3 vi CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 ...
Page 210: ...3 Tests and Diagnostics 3 31 SETUP 3 82 CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 ...
Page 224: ...3 Tests and Diagnostics 3 31 SETUP 3 96 CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 ...
Page 225: ...Chapter 4 Replacement Procedures CONFIDENTIAL ...
Page 226: ...4 Replacement Procedures 4 ii CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 ...
Page 232: ...4 Replacement Procedures 4 viii CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 ...
Page 371: ... CONFIDENTIAL Appendices ...
Page 372: ...Appendices App ii CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 ...
Page 408: ...Appendices Appendix B Board Layout B 22 CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 ...
Page 454: ...Appendices Appendix C Pin Assignments C 46 CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 ...
Page 464: ...Appendices Appendix E Key Layout E 2 CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 ...
Page 468: ...Appendices Appendix F Wiring diagrams F 4 CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 ...
Page 474: ...Appendices Appendix I Reliability I 2 CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 ...