3 Tests and Diagnostics
3.7 Memory Test
3-16
[CONFIDENTIAL]
TECRA M10 Maintenance Manual (960-685)
3.7 Memory
Test
To execute the Memory Test, select
2
from the DIAGNOSTIC TEST MENU, press
Enter
and follow the directions on the screen. Move the highlight bar to the subtest you want to
execute and press
Enter
.
Subtest 01
Conventional memory
This subtest writes a constant data to conventional memory (0 to 640 KB),
then reads the new data and compares the result with the original data.
Subtest 02
Protected Mode
NOTE: The CONFIG.SYS file must be configured without expanded memory manager
programs such as EMM386.EXE, EMM386.SYS or QEMM386.SYS. Also, the
HIMEM.SYS must be deleted from the CONFIG.SYS file.
This subtest writes constant data and address data (from 1MB to maximum
MB), and reads the new data and compares the result with the original data.
Subtest 03
Cache memory (on/off)
To test the cache memory, a pass-through write-read comparison of ‘5Ah’
data is run repeatedly to the test area (‘7000’: ‘Program’ size to ‘7000’:
‘7FFF’ (32 KB)) to check the hit-miss ratio (on/off status) for CPU cache
memory. One test takes 3 seconds.
Number of misses
<
Number of hits
→
OK
Number of misses
≥
Number of hits
→
Fail
Subtest 04
Stress
Write/Read buffer (1 size = B30h) is prepared in the conventional memory.
The data is made in the Write Buffer, the data in Write Buffer is written in the
area of address of 1MB or after. The data is red in the Read Buffer and data is
compared in area up to the maximum size.
Data: FFh, FFh, FFh, FFh, FFh, 00h, 00h, 00h, 00h,
FFh, FFh, FFh, 00h, FFh, 00h, 00h, FFh, 00h,
00h, FFh, FFh, FFh, FFh, 00h, 00h, 00h, AAh
Summary of Contents for Tecra M10
Page 11: ... CONFIDENTIAL Chapter 1 Hardware Overview ...
Page 12: ...1 Hardware Overview 1 ii CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 ...
Page 46: ...1 Hardware Overview 1 10 AC Adapter 1 32 CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 ...
Page 47: ... CONFIDENTIAL Chapter 2 Troubleshooting Procedures ...
Page 48: ...2 Troubleshooting Procedures 2 ii CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 2 ...
Page 52: ...2 Troubleshooting Procedures 2 vi CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 ...
Page 123: ... CONFIDENTIAL Chapter 3 Tests and Diagnostics ...
Page 124: ...3 Tests and Diagnostics 3 ii CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 3 ...
Page 128: ...3 Tests and Diagnostics 3 vi CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 ...
Page 210: ...3 Tests and Diagnostics 3 31 SETUP 3 82 CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 ...
Page 224: ...3 Tests and Diagnostics 3 31 SETUP 3 96 CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 ...
Page 225: ...Chapter 4 Replacement Procedures CONFIDENTIAL ...
Page 226: ...4 Replacement Procedures 4 ii CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 ...
Page 232: ...4 Replacement Procedures 4 viii CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 ...
Page 371: ... CONFIDENTIAL Appendices ...
Page 372: ...Appendices App ii CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 ...
Page 408: ...Appendices Appendix B Board Layout B 22 CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 ...
Page 454: ...Appendices Appendix C Pin Assignments C 46 CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 ...
Page 464: ...Appendices Appendix E Key Layout E 2 CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 ...
Page 468: ...Appendices Appendix F Wiring diagrams F 4 CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 ...
Page 474: ...Appendices Appendix I Reliability I 2 CONFIDENTIAL TECRA M10 Maintenance Manual 960 685 ...