11-22
11. PROGRAMMING PROCEDURES
11.12 CMT/PL-3
ENTER
2
PROG.
ESC.
<MENU>
Group 2
Main
<MENU>
SAVE
LOAD
or
NEXT
PLU
or
<MENU>
Group 2
Set the transmission item.
(Refer to table 4)
NOTES: 1. Press SAVE or LOAD key on the PL-3.
2. If the ENTER Key is not pressed within 10 seconds after SAVE or LOAD key is pressed,
a time out error will occur.
3. After pressing the ENTER key, the operation ends when “00” appears in the 7 seg. display
and LAMP goes off. Remove the data disc and turn the power off.
4. Be sure to start the PL-3 before the main operation.
Table 3: Error code during PL-3 operation
1) When the error code in FF, this system enters stop status. (Turn the power off/on for release.)
2) When the error code is F2 or FE, perform the status clear ( 9 9 ).
3) If an error occurs, refer to the PL-3 Owner’s Manual and solve the problem.
Error Code
Error Message
1
3
0
1
2
FDC ERROR
FDK MISINSERTION ERROR
UNAVAILABLE FDK INSERTION
ERROR
VOL. LABEL UNMATCH ERROR
FDK MEMORY FULL ERROR
WRITE PROTECT ERROR
NO SEARCH FILE ERROR
TIME OUT ERROR
LOAD ERROR
FDK ERROR
BUSY STATUS
POWER FAIL ERROR
OVERRUN ERROR
3
4
5
6
1
2
3
4
5
6
Error Code
Error Message
E
3
F
7
8
0
FRAMING ERROR
PARITY ERROR
DESIGNATED SELECT KEY
ERROR
DATA ERROR
STATUS ERROR
TIME OUT ERROR
FDK READ/WRITE ERROR
RAM READ/WRITE ERROR
ROM CRC ERROR
RAM BACK UP BATTERY ERROR
FDC DIAG LEVEL 0 ERROR
SYSTEM FDK LOADING ERROR
SYSTEM ERROR
1
2
3
F
0
1
2
3
E
F
PL-3 Operation
Connect the PL-3 to the SL-9000 by using RS-232C Cable, then turn on the power of the SL-9000 and
the PL-3.
Insert a data disc into the PL-3 and adjust the transmission rate to the SL-9000 ( 7 2 : 4800 BPS
or 7 3 : 2400 BPS) by using the rotary switch.
Press the SAVE key of the PL-3, then check whether the SAVE LED is on.
Program the file number of the data disc by using the rotary switch.
( 4 1 : File No. 1, 4 2 : File No. 2, ..... 4 8 : File No. 8, 4 9 : File No. 9)