14-4
14. OPERATING PROCEDURES
14.3 BY COUNT OPERATION
14.3 BY COUNT OPERATION
The BY-COUNT mode is used to issue the label of commodities of the same kind in a package (or may
not be packed). The whole package quantity (or a certain quantity) and the whole package price (or the
price per the quantity) are usually preset. Thus, it is not necessary to weigh the commodities by the scale
in such cases.
Menu: REG., M.DOWN, or REWRAP
Mode: BY-COUNT
Example) In case of purchasing 10 DONUTS for $1.50 of price for 4 DONUTS. (When a price of $1.50/
4 DONUTS is set for PLU #33.)
3
3
1
0
PLU
PRT
*
PRT
*
Single label is issued.
The label is issued in
succession after peeling it.
C
C
PLU
Enter the PLU #.
Enter the quantity of
purchase
(Max. 2 digits)
Press to suspend label
issue temporarily.
Press to cancel label
issue.
The display returns to
the initial screen.
Press to
resume label
issue.
AUTO
MANUAL
WEIGHT
UNIT PRICE TOTAL PRICE
-----
P
10
3.76
Liquid Crystal Display
DONUTS
REG
Remote Display
NET WT.
SELL BY
PACKED ON
PRICE lb
NET WT.
SELL BY
PACKED ON
PRICE lb
(Sample label for US type)
(Sample label for CA and QR type)
TEC STORE
(TEL) 0123-45-6789
TEC STORE
(TEL) 0123-45-6789