3-28
6.
The Hard Disk Test message appears after you respond to the Detail Status prompt.
Select the number of the subtest you want to execute and press
Enter
. The follow-
ing message displays during each subtest.
HARD DISK TEST XXXXXXX
SUB-TEST : XX
PASS COUNT: XXXXX ERROR COUNT: XXXXX
WRITE DATA: XX READ DATA : XX
ADDRESS : XXXXXX STATUS : XXX
The first three digits of the ADDRESS indicate which cylinder is being tested, the
fourth digit indicates the head, and the last two digits indicate the sector.
The first digit of the STATUS number indicates the drive being tested, and the last
two digits indicate the error status code as explained in Table 3-3 in Section 3-14.
Subtest 01
Sequential Read
This subtest is a sequential reading of all the tracks on the HDD starting at
Track 0. When all the tracks on the HDD have been read, the test starts at the
maximum track and reads the tracks on the HDD sequentially back to Track 0.
Subtest 02
Address Uniqueness
This subtest writes unique address data to each sector of the HDD track-by-
track. The data written to each sector is then read and compared with the
original data. There are three ways the HDD can be read:
• Forward sequential
• Reverse sequential
• Random
Subtest 03
Random Address/Data
This subtest writes random data to random addresses on the HDD cylinder,
head and sector. This data is then read and compared to the original data.
Summary of Contents for T1950
Page 21: ...2 3 Figure 2 1 Troubleshooting Flowchart 1 2 ...
Page 156: ...B 2 Figure B 2 FATSU Upper System Board back G ...
Page 158: ...B 4 B 2 FATSL Lower System Board Figure B 3 FATSL Lower System Board front ...
Page 159: ...B 5 Figure B 4 FATSL Lower System Board back ...
Page 171: ...D 1 Appendix D USA Display Codes Table D 1 USA Display Codes ...