Check 2
If either of the following error messages [(a) or (b)] is displayed on the screen,
press any key as the message instructs.
(a) WARNING: RESUME FAILURE.
PRESS ANY KEY TO CONTINUE.
(b) WARNING: DATA IN HARD-RAM WAS LOST.
YOU MUST FORMAT HARD-RAM BEFORE USE.
PRESS ANY KEY TO CONTINUE.
Error Message (a) appears when data stored in RAM under the resume function is
lost because the battery has become discharged or the system PCB is damaged. Go
to Procedure 3.
Error Message (b) appears when the error is detected during a read test of the
Hard RAM or the data in Hard RAM is lost because the battery has become
discharged.
If any other message appears, perform Check 3.
Check 3
The IRT checks the system boards. When the IRT detects an error, the system stops
or an error message appears. Refer to Table 2-1 for a list of error messages.
Table 2-1 IRT Error Messages (1/2)
No.
Error Message
1
TIMER CH.2 OUT ERROR
2
PIT ERROR
3
MEMORY REFRESH ERROR
4
FIRST 64KB MEMORY ERROR
5
RTC ERROR
6
CRTC ERROR
7
VRAM ERROR
8
KBC ERROR
9
SYSTEM MEMORY ERROR
10
SYSTEM MEMORY PARITY ERROR
11
EXTENDED MEMORY ERROR
12
EXTENDED MEMORY PARITY ERROR
13
DMA PAGE REGISTER ERROR
14
DMAC #1 ERROR
15
DMAC #2 ERROR
16
PIC #1 ERROR
Summary of Contents for T1950
Page 21: ...2 3 Figure 2 1 Troubleshooting Flowchart 1 2 ...
Page 156: ...B 2 Figure B 2 FATSU Upper System Board back G ...
Page 158: ...B 4 B 2 FATSL Lower System Board Figure B 3 FATSL Lower System Board front ...
Page 159: ...B 5 Figure B 4 FATSL Lower System Board back ...
Page 171: ...D 1 Appendix D USA Display Codes Table D 1 USA Display Codes ...