400 Series
4-45
4.20 400CS FL
NOTE
: When you remove the
FL
, be careful not to let any dust or other foreign
matter enter the display panel components.
Removing the 400CS FL
To remove the 400CS FL, follow the steps below. Refer to figures 4-39 through 4-42.
1.
Turn off the power to the 400CS. Disconnect the AC power cable, and all exter-
nal cables connected to the 400CS.
2.
Remove the battery pack, optional memory module, optional PCMCIA card,
display mask, FL inverter board and LCD module as described in sections 4.2, 4.3,
4.4, 4.16, 4.17, and 4.19.
3.
Carefully unbend
11 latches
securing the
LCD module
to its frame.
4.
Turn the
LCD module
over and remove
four screws
. Note that the two screws on
the FL inverter cable side of the module are smaller.
Figure 4-39 Unbending the color LCD module latches and removing screws
5.
Lift the LCD module out of the frame.
6.
Gently grip the
FL cable connector
with a pair of needle nose pliers and discon-
nect the
FL cable
. Be very careful not to damage the connector or cable.