3
EN
ENGL
ISH
FR
ANÇAIS
DEUTSCH
IT
ALIANO
ESP
AÑOL
ΕΛΛΗΝΙΚΗ
PO
R
T
U
G
U
ÊS
##
#SW##
#
##
#R
U##
#
Separate sold parts
• Connecting pipe (Liquid side)
(6.4 mm (diam.), Nominal (diam.) 1/4" thick 0.8 mm)
• Connecting pipe (Gas side)
(9.5 mm (diam.), Nominal (diam.) 3/8" thick 0.8 mm)
RAS-M10SMUV-E, RAS-M10SMUCV-E, RAS-M13SMUV-E, RAS-M13SMUCV-E
(12.7 mm (diam.), Nominal (diam.) 1/2" thick 0.8 mm)
RAS-M16SMUV-E, RAS-M16SMUCV-E
• Power supply cord
2.5 mm
2
(H07RN-F or 60245IEC66)
• Connecting wire
1.0 mm
2
(H07RN-F or 60245IEC66)
• Thermal insulation for refrigerant pipe (10 mm or more, thermal insulating foam polyethylene)
• Thermal insulation for drain pipe (10 mm or more, foam polyethylene)
• Drain pipe (Outer 26 mm (diam.))
• Tapes
• Grounding wire (1.6 mm (diam.) or more)
2 ACCESSORY PARTS AND PARTS TO BE PROCURED
LOCALLY
Accessory parts
Part name
Q'ty
Shape
Usage
Installation Manual
1
This manual
(Be sure to hand over to customers)
Wireless remote controller
1
—
Remote controller holder
1
—
Mounting screws for remote
controller holder
3.1 mm (diam.) × 16 mm
1
—
Batteries (Manganese)
2
—
Heat insulating pipe
2
For heat insulation of pipe connecting section
Installation pattern
1
—
For confirmation of ceiling opening and main unit position
Installation gauge
2
For positioning of ceiling position (united with installation
pattern)
Pattern fixing screw
4
M5 × 16L
For attach the installation pattern
Heat insulator
1
For heat insulation of drain connecting section
Washer
8
For hanging-down unit
Hose band
1
For connecting drain pipe
Flexible hose
1
For adjusting core-out of drain pipe
Heat insulator A
1
For sealing of wire connecting port
Heat insulator B
1
For sealing of wire connecting port
Owner’s Manual
1
(Be sure to hand over to customers)
Part name
Q'ty
Shape
Usage
Ceiling panel
1
Model: RB-B11MC(W)E
Parts to be procured locally