7 m
60
90
7 m
7 m
45
45
60
100
45
45
45
45
100
70
60
100
230
150
(700)
(600)
(205)
15
15
90
15
15
272
560
59
0
670
10-3. Indoor Unit
10-3-1. Installation Place
Remote control
•
A place where there are no obstacles such as a curtain that may block the
signal from the remote control.
•
Do not install the remote control in a place exposed to direct sunlight or
close to a heating source such as a stove.
•
Keep the remote control at least 1 m apart from the nearest TV set or
stereo equipment (This is necessary to prevent image disturbances or
noise interference).
•
The location of the remote control should be determined as shown below.
10-3-2. Cutting a Hole and Mounting
When the installation plate is directly mounted
on the wall
1. Securely fil t the installation plate onto the wall by screwing it in the upper
and lower parts to hook up the indoor unit.
2. To mount the installation plate on a concrete wall with anchor bolts, use
the anchor bolt holes as illustrated in the below fi gure.
3. Install the installation plate horizontally in the wall.
NOTE
•
When drilling a wall that contains a metal lath, wire lath or metal plate, be
sure to use a pipe hole brim ring sold separately.
•
A place which provides the spaces around the indoor unit as shown in the
diagram.
•
A place where there are no obstacles near the air inlet and outlet.
•
A place which allows easy installation of the piping to the outdoor unit.
•
A place which allows the front panel to be opened.
•
In case of block, brick, concrete or similar type walls, make
∅
5 mm holes
in the wall.
•
Insert clip anchors for appropriate mounting screws 6 .
Installation plate
(Keep horizontal direction)
ˇ 5 mm hole
Clip anchor
(local parts)
Anchor bolt
Projection
15 mm or less
Cutting a hole
Mounting the installation plate and screw position
•
Direct sunlight to the indoor unit's wireless receiver should be avoided.
•
The microprocessor in the indoor unit should not be too close to RF
noise sources.
(For details, see the owner's manual)
1. After determining the pipe hole position, drill the pipe hole (
∅
65 mm) at a
slight downward slant to the outdoor side.
6
Mounting screw
∅
4 mm x 25
l
Failure to fi rmly install the unit may result in personal injury and property
damage if the unit falls.
Remote
control
Indoor unit
Reception range
(Side view)
(Top view)
Reception range
* : Axial distance
: Pipe hole (ˇ 65 mm)
(Side piping)
(Rear piping)
(Bottom piping)
(Unit : mm)
Floor
Wall
Remote control
Installation Plate
CAUTION
CAUTION
CAUTION
FILE NO. SVM-18048
- 61 -