(Table 2) Indoor fan air flow rate <Heating>
Fan speed
level
Fan speed
Air flow rate
Fan speed
Air flow rate
Fan speed
Air flow rate
(rpm)
(m3/h)
(rpm)
(m3/h)
(rpm)
(m3/h)
WF
UH
560
528
600
570
690
666
WE
H
540
510
580
552
670
642
WD
M+
480
443
520
486
59
0
570
WC
440
408
4
70
4
35
570
540
WB
M
430
3
99
460
426
520
486
WA
380
342
410
3
76
460
426
W9
L+
3
70
334
400
366
460
426
W8
L
3
20
282
340
300
400
366
W7
L-
260
216
270
228 360
324
W6
260
216
270
228
340
300
W5
UL
260
216
270
228
340
300
W4
260
216
270
228
340
300
W3
260
216
270
228
340
300
W2
SUL
240
198
250
210
320
282
W1
240
198
240
198
240
198
HEAT
Item
Operation flow and applicable data, etc.
Description
[In starting and in stability]
FAN AUTO
FAN Manual
In starting
• Until 12 minutes passed after operation start
• When 12 to 25 minutes passed after operation
start and room temp. is 3°C or lower than set temp.
• Room temp. < Set temp. –4°C
In stability
• When 12 to 25 minutes passed after operation start
and room temp. is higher than (set temp. –3°C)
• When 25 minutes or more passed after operation start
• Room temp.
=
Set temp. –3.5°C
RAS-B13U2FVG
Series
RAS-B18U2FVG
Series
RAS-B10U2FVG
Series
FILE NO. SVM-18048
- 30 -