Item
2. Indoor fan
motor control
Operation flow and applicable data, etc.
<In cooling operation>
(This operation controls the fan speed at indoor unit side.)
The indoor fan (cross flow fan) is operated by the phase-
control induction motor. The fan rotates in 5 stages in
MANUAL mode, and in 5 stages in AUTO mode, respec-
tively. (Table 1)
Description
* Symbols
UH
: Ultra High
H
: High
M+
:
M
: Medium
L+
: Low+
L
: Low
L-
: Low–
UL
: Ultra Low
SUL
: Super Ultra Low
* The fan speed broadly varies due
to position of the louver, etc.
The described value indicates one
under condition of inclining
downward blowing.
1) When setting the fan speed to L,
L+, M, M+ or H on the remote
controller, the operation is
performed with the constant
speed shown in Fig. 1.
2) When setting the fan speed to
AUTO on the remote controller,
revolution of the fan motor is
controlled to the fan speed level
shown in Fig. 2 and Table 1
according to the setup tempera-
ture, room temperature, and heat
exchanger temperature.
(Fig. 1)
(Fig. 2)
L
L+
M
M+
H
W7
(L + M) / 2
WA
(M + H) / 2
WD
Indication
Fan speed
Fan speed setup
COOL ON
AUTO
+2.5
TA-Tsc
[°C]
+2.0
+1.5
+1.0
+0.5
Tsc
a
b
c
d
e
M+(WC)
*3
*4
*5
L(W7)
MANUAL
*3 : Fan speed = (M +
−
L) x 3/4 + L
*4 : Fan speed = (M +
−
L) x 2/4 + L
*5 : Fan speed = (M +
−
L) x 1/4 + L
(Linear appro ximation
from M+ and L)
Hi Power
Fan speed
H+(WD)
*6
*7
*8
L+(W8)
*6 : Fan speed = (H
−
L+) x 3/4 + L+
*7 : Fan speed = (H
−
L+) x 2/4 + L+
*8 : Fan speed = (H
−
L+) x 1/4 + L+
(Linear appro ximation
from H and L+)
Hi-POWER
W8
(L + M) / 2
WC
(M + H) / 2
WE
Fan speed
level
Fan speed
Air flow rate
Fan speed
Air flow rate
Fan speed
Air flow rate
(rpm)
(m3/h)
(rpm)
(m3/h)
(rpm)
(m3/h)
WF
530
498
560
528
650
624
WE
UH
530
498
560
528
650
624
WD
H
500
468
540
510
630
600
WC
M+
450
414
490
459
560
528
WB
4
50
4
1
4
4
90
4
59
560
528
WA
M
400
366
440
408
500
468
W9
360
324
390
354
450
414
W8
L+
3
50
3
15
3
90
3
54
450
414
W7
L
300
258
340
300
400
366
W6
L
−
260
216
270
228
360
324
W5
UL
260
216
270
228
340
300
W4
240
198
250
210
320
282
W3
SUL
240
198
240
198
300
258
W2
240
198
240
198
300
258
W1
240
198
240
198
300
258
RAS-B13U2FVG
Series
RAS-B18U2FVG
Series
Cool
RAS-B10U2FVG
Series
(table 1) Indoor fan air flow rate <Cooling>
FILE NO. SVM-18048