9-2-5. Piping and Drain Hose Installation
In case of rightward piping
• After scribing slits of
the front cabinet and
the rear panel by a
knife or a marking-off
pin, cut them by a pair
of nippers or the like.
NOTE
If the pipe is bent incorrectly, the indoor unit may
unstably be set on the wall.
After passing the connecting pipe through the pipe
hole, connect the connecting pipe to the auxiliary
pipes and wrap the facing tape around them.
CAUTION
• Bind the auxiliary pipes (two) and connecting
cable with facing tape tightly. In case of left-
ward piping and rear-leftward piping, bind the
auxiliary pipes (two) only with facing tape.
Fig. 9-2-10
In case of downward piping
• After scribing the slit of
the front cabinet and
slit in the lower part of
the rear panel by a knife
or a marking-off pin,
cut them by a pair of
nippers or the like.
Fig. 9-2-11
Left-hand connection with piping
Bend the connecting pipe so that it is laid within 43
mm above the wall surface. If the connecting pipe is
laid exceeding 43 mm above the wall surface, the
indoor unit may unstably be set on the wall. When
bending the connecting pipe, make sure to use
spring bender so as not to crush the pipe.
Bend the connection pipe within a radius of 30
mm.
To connect pipe after installation of unit (figure)
Fig. 9-2-12
Fig. 9-2-13
• Carefully arrange pipes so that any pipe does
not stick out of the rear plate of the indoor unit.
• Carefully connect the auxiliary pipes and
connecting pipes to each other and cut off the
insulating tape wound on the connecting pipe
to avoid double-taping at the joint, moreover,
seal the joint with the vinyl tape, etc.
• Since dewing results in a machine trouble,
make sure to insulate both the connecting
pipes.
(Use polyethylene foam as insulating material.)
• When bending a pipe, carefully do it not to
crush it.
Slit (rear panel)
Slit
(front cabinet)
Slit (rear panel)
Slit
(front cabinet)
196mm
96mm
Liquid side
Gas side
Outward form of indoor unit
(To the forefront of flare)
R 30mm (Use polisin or the like for bending pipe.)
43mm
Use the handle of screwdriver,etc.
80
˚
Indoor unit
Connecting
cable
Installation
plate
Auxiliary
pipes