– 67 –
• When the installation plate is directly
mounted on the wall
1. Securely fit the installation plate onto the wall by
screwing it in the upper and lower parts to hook
up the indoor unit.
2. Install the installation plate using 4 to 6 pieces of
mounting screw securing four corners with
screws.
3. Install the installation plate horizontally in the
wall.
9-2-4. Wiring Connection
How to connect the inter-connect cable
• After removing the front cabinet, remove the
terminal cover and the cord clamp.
• Connect and secure the inter-connect cable and
secure the cord clamp and the terminal cover.
• Be sure to smooth out the notch with a file, etc.
CAUTION
• Be sure to refer the wiring system diagram
labeled inside the front panel.
• Check local electrical codes and also any
specific wiring instructions or limitation.
Fig. 9-2-4
• In the case of a reinforced concrete wall
1. In the selected area on the reinforced concrete
wall, bore holes at intervals of 450 mm, and drive
clip anchors or hole in anchors into them.
2. Attach the installation plate to the wall by screw-
ing bolts or nuts into the anchors. However, in the
case where hole in anchors are used, the depth
of the holes should be adjusted so that the nut-
heads extend no more than 15 mm.
Fig. 9-2-5
• In the case of the BRICK wall
Fig. 9-2-6
CAUTION
When installing the installation plate with mount-
ing screw, do not use the anchor bolt hole.
Otherwise the unit may fall down and result in
personal injury and property damage.
Fig. 9-2-7
Stripping length of connecting cable
NOTE
Use stranded wire only.
WIRE TYPE : more than H05 RN-F
Fig. 9-2-8
NOTE
Connect the earth line to the metallic part (
mark)
located at the side of 3P terminal.
Fig. 9-2-9
Anchor bolt
Projection
15mm or less
Concrete wall
Concrete wall
Installation
plate
Hole in anchor
Bolt
Hole in anchor
Installation plate
Nut with threaded
hole 8 mm dia.
Less than 15 mm
5 mm dia. hole
Clip anchor
(local parts)
9 Mounting screw
Connecting
cable
about 15cm
Terminal block
Cord
clamp
Screw
Screw
Connecting
cable
Earth line
Terminal
cover
Screw
Earth
line
10mm
10mm
1 2 3
40mm
50mm
1 2 3