– 103 –
Reactor
Flange nut
Propeller fan
Fan
motor
Partition board
Valve
clamping
plate
Compressor
thermo.
Compressor
No.
Part name
Fan motor
Procedure
1) Perform work from item 1) to 5), 7) of
.
2) Remove the flange nut fixing the fan motor and the
propeller fan.
• Flange nut is loosened by turning clockwise.
(To tighten the flange nut, turn counterclock-wise.)
3) Remove the propeller fan.
4) Disconnect the connector for fan motor from the inverter.
5) Remove the fixing screws (3 pcs.), while holding by
hands so that the fan motor does not fall.
Compressor
Reactor
Remarks
1) Perform work of item
,
and
.
2) Evacuate refrigerant gas.
3) Remove the partition board.
(Take care that the reactor and the partition fixing plate
remain.) (Ø4 x 10 3 pcs.)
4) Remove the sound-insulation materials.
5) Remove terminal cover of the compressor, and discon-
nect lead wires of the compressor and the compressor
thermo. assembly from the terminal.
6) Remove pipes connected to the compressor with a
burner.
7) Remove the fixing screws of the bottom plate and heat
exchanger. (Ø4 x 10 2 pcs.)
8) Remove the fixing screws of the bottom plate and valve
clamping plate (Ø4 x 10 2 pcs.), the accumulator fixing
plate and the accumlator (Ø4 x 10 2 pcs.).
9) Pull upward the refrigeration cycle.
10) Remove nut fixing the compressor on the bottom plate.
1) Perform work from item 1) to 5) of
and
.
2) Remove screws fixing the reactor. (Ø4 x 10 2 pcs. for
one reactor. One outdoor unit has two reactors on the
partition.)