– 25 –
Outdoor Unit : RAS-3M26YAV-E
<Heating>
NOTE :
Model of Indoor unit 10 : RAS-M10YKV-E, 13 : RAS-M13YKV-E, 16 : RAS-M16YKV-E
MCA : Minimum Circuit Amps.
ICF
: Maximum Instantaneous Current Flow (Equivalent to MCA in case of inverter air conditioner)
MOCP : Maximum Overcurrent Protection (Fuse only)
MSC : Maximum Starting Current
FLA
: Full Load Amps.
RLA
: Rated Load Amps. RLA under conditions on the right.
DB
WB
Indoor temp.
(°C)
20
—
Outdoor temp. (°C)
7
6
System
Compressor
Fan motor FLA
Voltage range
Power supply
Combination of
indoor unit operation
Hz
Volts-
Ph.
Min.
Max.
MCA
ICF
MOCP
(Amps)
MSC
RLA
Indoor
Outdoor
10
–
–
8.15
8.15
20
6.00
6.00
0.15 x 1 = 0.15
0.5
13
–
–
11.20
11.20
20
8.44
8.44
0.15 x 1 = 0.15
0.5
1 unit
16
–
–
13.15
13.15
20
10.00
10.00
0.15 x 1 = 0.15
0.5
10
10
–
11.16
11.16
20
8.29
8.29
0.15 x 2 = 0.30
0.5
13
10
–
12.23
12.23
20
9.14
9.14
0.15 x 2 = 0.30
0.5
16
10
–
13.00
13.00
20
9.76
9.76
0.15 x 2 = 0.30
0.5
13
13
–
13.00
13.00
20
9.76
9.76
0.15 x 2 = 0.30
0.5
16
13
–
14.00
14.00
20
10.56
10.56
0.15 x 2 = 0.30
0.5
2 units
16
16
–
14.78
14.78
20
11.18
11.18
0.15 x 2 = 0.30
0.5
10
10
10
12.51
12.51
20
9.25
9.25
0.15 x 3 = 0.45
0.5
13
10
10
12.85
12.85
20
9.52
9.52
0.15 x 3 = 0.45
0.5
16
10
10
13.24
13.24
20
9.83
9.83
0.15 x 3 = 0.45
0.5
13
13
10
13.24
13.24
20
9.83
9.83
0.15 x 3 = 0.45
0.5
16
13
10
13.24
13.24
20
9.83
9.83
0.15 x 3 = 0.45
0.5
13
13
13
13.24
13.24
20
9.83
9.83
0.15 x 3 = 0.45
0.5
16
16
10
13.58
13.58
20
10.10
10.10
0.15 x 3 = 0.45
0.5
16
13
13
13.58
13.58
20
10.10
10.10
0.15 x 3 = 0.45
0.5
3 units
16
16
13
50 or 60
230–1
198
264
13.90
13.90
20
10.36
10.36
0.15 x 3 = 0.45
0.5