– 56 –
(8) ECONO. operation control
When the ECONO. button of the remote controller is pushed, quiet and mild operation is performed by
restraining air flow and operating motor speed.
1) Indoor air flow is controlled between SUL and L– (Low air (–)).
2) Setting M10 at 20 rps, M13 at 20 rps and M16 at 20 rps as the maximum operating compressor motor
speed, the minimum capacity operation range is widened every 1 hour and 2 hours have passed after
ECONO. operation had started.
3) Maximum operating compressor motor speed lowers up to 37 rps when the ECONO. instruction is sent
from even a room.
Fig. 8-2-5
8-2-3. DRY Operation
(The Remote controller MODE Button
is Set to the DRY Position)
• Once the setting is made, the operation mode is
memorized in the microcomputer so that the same
operation can be effected thereafter simply by
pushing [START/STOP] button.
• Dry operation signal is transmitted to outdoor unit.
• The Cooling operation giving priority to dehumidi-
fying, which restrains the indoor fan speed and
compressor motor speed, is performed.
• The indoor fan motor operates as shown in Fig. 8-
2-6. (Fan speed is AUTO only.)
• The outdoor unit controls the outdoor fan relay
R01, R02 and R03, and the compressor motor
speed according to the operation command signal
sent from the indoor unit.
–0.5
0
+0.5
+1.0
+1.5
+2.0
+2.5
*1
L–
SUL
(Room temp
.)
–
(Set temp
.)
Set
temp.
0,5
1
1.5
2
2.5
3
3.5
(Room temp
.)
–
(Set temp
.)
Air volume
Compressor motor speed
20 rps
20 rps
SUL
20 rps
20 rps
L–
20 rps
20 rps
20 rps
20 rps
33 rps
37 rps
32 rps
20 rps
20 to 33 rps
31 rps
31 to 37 rps
31 rps
31 to 32 rps
20 rps
(L– + UL)/2
M13
1 unit
M16
2 units
3 units
4 units
M10
Time
2H
1H
NOTE :
*
1 : Middle motor speed between L– and SUL
Fig. 8-2-6 Setting of air flow