FILE NO. SVM-09036
10-2. Outdoor Unit
1) Stop the operation of the air conditioner and turn off
its main power supply or remove the power supply
cord.
3) Remove 2 cord clamps (4 screws
∅
4 x 16L) and
disconnect the power supply cord and connecting
cable after removing 6 screwson on the terminal
block and 1 ground screw on the electrical parts
base.
No. Part name Procedures Remarks
Front cabinet
Side cabinet
2) Remove the packed valve cover and the
electrical parts cover (2 screws
∅
4 x 10L)
4) Remove the top cabinet. (7 screws
∅
4 x 10L)
(Pulling out upward)
5) Remove the top cabinet. (2 screws
∅
4 x 10L)
(Pull the front right portion toward you, and
remove it pulling out upward)
Top cabinet
Front
cabinet
2 screws
∅
4 x 10L
4 screws
∅
4 x 16L
2 Cord clamps
7 screws
∅
4 x 10L
Packed valve cover
-
74
-
j
Common
procedure